JVC KY-F70BU Instruction Manual - Page 28
Settings and adjustments for recording
View all JVC KY-F70BU manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 28 highlights
3. Settings and adjustments for recording Setting the dip switches The type of PC monitor to use and the ID during SCSI connection are set using the dip switches. Dip switches SCSI REC SEND AW/SEL MODE MENU UP DOWN SET PLAY FREEZE MONITOR LENS REMOTE ON 1 2 3 4 DC IN POWER SEE INSTRUCTION MANUAL CAUTION Turn the power off before setting the dip switches. Setting the switches with the power on will not change the settings. Monitor output settings Dip switch no. 3 is set depending on whether using a system which uses a commercially available VGA monitor or a system which uses a capture board. ON 1 2 3 4 Set to OFF ON 1 2 3 4 Set to ON VGA output setting Set when directly connecting a VGA monitor to the MONITOR terminal on the rear of the main unit. SXGA output setting Set for systems using a capture board. The signal from the MONITOR terminal on the rear of the main unit is inputted through the analog input compatible video capture board. ( ੬ Page 68 Capturing images using the image capture board) SCSI ID settings DiP switches 1 and 2 are set depending on the used system to set the SCSI ID. ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ID=7 ID=6 ID=5 ID=4 E24 Set when connecting a printer or MO drive unit directly to the main unit. When making this setting, the main unit will become the initiator. Set when exporting images to a PC. Make sure that the ID numbers of the connecting devices are not the same. When making this setting, the PC will become the initiator and the main unit will become the target. ( ੬ Page 66 Connecting to a PC)