JVC V25U Startup Guide - Page 10

Side / Rear, Fall Prevention Wire Mounting Screw

Page 10 highlights

Getting Started Side / Rear JK MONITOR OUT PAL OFF NTSC RESET STATUS IRIS ML J [MONITOR OUT] Monitor Output Selection Switch Use this switch to select the availability of output from the N [MONITOR OUT] terminal as well as the signal system. NTSC : Outputs NTSC signals. OFF : No output. Select this value when distributing images to the network. PAL : Outputs PAL signals. [Default setting: OFF] Caution: ● Images are not distributed to the network when ANTSCB or APALB is selected. ● When the switch is changed, press the K Reset button to reboot the unit. K [RESET] Reset Button This is a button for rebooting the camera. Press this button and release within 5 seconds to reboot the camera. It takes about one minute for the camera to reboot. During startup, the [RESET] button is disabled. Note: Pressing the [RESET] button for 5 seconds or longer switches the camera to the service verification mode. Do not press the button for 5 seconds or longer. L [IRIS] Iris Terminal Use this terminal to connect the DC iris lens. (Connection with the video iris lens is not possible.) (A Page 13) M [STATUS] Status Indicator This status of this product is indicated in green or orange color. Starting up: Lights up in orange Startup complete: Lights up in green Error: Blinking (orange or green) 10 Q 1 2 P G2 12 1 OUTPUT INPUT CLASS 2 ONLY FOR USA ISOLATED POWER ONLY FOR EUROPE AND OTHER AC24V ALARM PoE MONITOR OUT 10BASE-T/ SEE INSTRUCTION MANUAL 100BASE-TX CAUTION: NEVER USE PoE AND AC 24V AT THE SAME TIME DO NOT CONNECT TO THE TELEPHONE NETWORK PUSH R NO Note: You can adjust the [LED State] settings via the network to turn off the indicator after startup is complete. N [MONITOR OUT] Monitor Video Signal Output Terminal (RCA) This is an output terminal for composite video signals (1 V (p-p), output impedance of 75 K). Use this terminal to connect to devices such as a video monitor. This terminal is used for adjusting the camera angle during installation. (A Page 16) Note: ● Use the J [MONITOR OUT] switch to select the availability of output as well as the signal system. When the switch is changed, press the K Reset button to reboot the unit. ● When using the [MONITOR OUT] output, set the privacy mask to AOffB. O [10BASE-T/100BASE-TX] Use this terminal to connect to the network via a LAN cable. This product supports PoE (IEEE802.3af class 2) and therefore can be used without a power cable. (A Page 14)(A Page 16) P [ALARM INPUT/OUTPUT] Alarm Input/ Output Terminals Use these terminals to connect to an external alarm device. (A Page 17) Q [AC24V] Power Input Terminal Use this terminal to connect to an AC 24 V, 50/60 Hz power supply. (A Page 15) R Fall Prevention Wire Mounting Screw (M3 x 6 mm) Use this screw to mount the fall prevention wire. (A Page 18)

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

10
Getting Started
Side / Rear
J
[MONITOR OUT] Monitor Output Selection
Switch
Use this switch to select the availability of output
from the
N
[MONITOR OUT] terminal as well as
the signal system.
NTSC
:
Outputs NTSC signals.
OFF
:
No output. Select this value when
distributing images to the network.
PAL
:
Outputs PAL signals.
[Default setting: OFF]
Caution:
Images are not distributed to the network
when
A
NTSC
B
or
A
PAL
B
is selected.
When the switch is changed, press the
K
Reset button to reboot the unit.
K
[RESET] Reset Button
This is a button for rebooting the camera. Press
this button and release within 5 seconds to
reboot the camera.
It takes about one minute for the camera to
reboot. During startup, the [RESET] button is
disabled.
Note:
Pressing the [RESET] button for 5 seconds or
longer switches the camera to the service
verification mode. Do not press the button for 5
seconds or longer.
L
[IRIS] Iris Terminal
Use this terminal to connect the DC iris lens.
(Connection with the video iris lens is not
possible.)
(
A
Page 13)
M
[STATUS] Status Indicator
This status of this product is indicated in green
or orange color.
Starting up: Lights up in orange
Startup complete: Lights up in green
Error: Blinking (orange or green)
Note:
You can adjust the [LED State] settings via the
network to turn off the indicator after startup is
complete.
N
[MONITOR OUT] Monitor Video Signal
Output Terminal (RCA)
This is an output terminal for composite video
signals (1 V (p-p), output impedance of 75
K
).
Use this terminal to connect to devices such as a
video monitor.
This terminal is used for adjusting the camera
angle during installation. (
A
Page 16)
Note:
Use the
J
[MONITOR OUT] switch to select
the availability of output as well as the signal
system. When the switch is changed, press
the
K
Reset button to reboot the unit.
When using the [MONITOR OUT] output, set
the privacy mask to
A
Off
B
.
O
[10BASE-T/100BASE-TX]
Use this terminal to connect to the network via a
LAN cable.
This product supports PoE (IEEE802.3af class 2)
and therefore can be used without a power cable.
(
A
Page 14)(
A
Page 16)
P
[ALARM INPUT/OUTPUT] Alarm Input/
Output Terminals
Use these terminals to connect to an external
alarm device.
(
A
Page 17)
Q
[AC24V] Power Input Terminal
Use this terminal to connect to an AC 24 V,
50/60 Hz power supply.
(
A
Page 15)
R
Fall Prevention Wire Mounting Screw
(M3 x 6 mm)
Use this screw to mount the fall prevention wire.
(
A
Page 18)
CAUTION
: NEVER U
S
E
PoE
AND
AC 24V
AT THE
S
AME TIME
DO NOT CONNECT TO THE TELEPHONE NETWORK
S
EE IN
S
TRUCTION MANUAL
CLA
SS
2 ONLY FOR U
S
A
I
S
OLATED POWER ONLY
FOR EUROPE AND OTHER
MONITOR
OUT
10BA
S
E-T/
100BA
S
E-TX
PU
S
H
S
TATU
S
MONITOR OUT
IRI
S
PAL
OFF
NT
S
C
RE
S
ET
OUTPUT
INPUT
2
AC24V
1
PoE
G
2
1
2
1
ALARM
K
Q
P
J
L
M
N
O
R