PROBLEM DRIP FROM RELIEF VALVE THERMOSTAT SHUT OFF COMBUSTION FAILS TO ODORS POSSIBLE CAUSE(S) 1. Excessive water pressure 2. Closed water system 1. Non-functioning thermostat 2. Improper calibration 1. Insufficient air SMOKING AND CARBON FORMATION (SOOTING) CONDENSATION BURNER FLAME FLOATS AND LIFTS OFF PORTS 2. Water heater flue or vent system blocked. 3. Heater installed in a confined area 1. Flammable vapor incident 1. Temperature setting too low 1. Orifice too large 2. High gas pressure 3. Water heater flue or vent system blocked. 4. Cold drafts 5. Dirty burner screen FLAME BURNS AT ORIFICE PILOT FLAME TOO SMALL 1. Non-functioning thermostat 2. Low gas pressure 3. Non-functioning burner 1. Pilot line or orifice clogged 2. Low gas pressure 3. Dirty pilot CORRECTIVE ACTION 1. Use a pressure reducing valve and relief valve 2. See "Thermal Expansion" 1. Replace thermostat 2. Replace thermostat 1. Provide ventilation to water heater. Check flue way, flue baffle, and burner 2. Clean, locate source and correct 3. Provide fresh air ventilation 1. Call 1-800-4-MY-HOME _'(1-800-469-4663) 1. Increase the temperature setting 1. Replace with correct orifice 2. Check with gas utility company 3. Clean flue and burner-locate source and correct 4. Locate source and correct 5. Clean burner screen. See "Ultra Low NOx Natural Gas Burner" section of this manual. 1. Replace thermostat 2. Check with gas utility company 3. Replace burner assembly 1. Clean, locate source and correct 2. Check with gas utility company 3. Clean pilot 29