Kenmore 3314 Owners Manual - Page 18

For Your Safety, Read Before, Ughting

Page 18 highlights

FOR YOUR SAFETY READ BEFORE UGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. BEFORE OPERATING: ENTIRE SYSTEM MUST BE FILLED W}TH WATER AND AIR PURGED FROM ALL LINES. A. This appliance has a pilot which is lit by a piezo electric gas ignition system. Do not open the inner door of the appliance and try to light the pilot by hand. B. BEFORE UGHTING smell all around the applianoe area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IFYOU SMELL GAS: Do not try to light any appliance. Do not touch any electric switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. If you cannot reach your gas supplier, call the fire department. C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part has been under water. Immediately contact a qualified installer or service agency to replace a flooded water heater. Do not attempt to repair the unit! It must be replaced! UGHTING iNSTRUCTiONS FmGURE "A" HGURE "g" HGURE "C" MAI_ 8U_NER / GAS CONTROL "OFF POSITION "PILOT" POSITION TOPKNOB "ON" POSITRON FIGURr: "D" 1, STOPI Read the safety information above on this label. 2. Set the thermostat to lowest setting (PILOT LIGHTING). 9. Once the pilot has been found, push the gas knob all the way down. Immediately press the pilot igniter button rapidly (4) to (5) times. If the pilot will not light, repeat step (3) Turn thermostat dial fully clockwise t_ until it stops. through (9). 3. Push the gas control knob down slightly and turn clockwise 10. Continue to hold the gas control knob down for about one f_ to"OFF", SEE FIGURE 'W'. NOTE: Knob CANNOT be turned from "PILOT" to "OFF" (!) minute after the pilot is lit. Release the gas control knob and it will pop back up. Pilot should remain lit. If it goes out, unless it is pushed down slightly. Do not force. 4, Remove the outer burner door located below the gas control. repeat step (3) through (9). It may take several minutes for air to clear the lines before the pilot will light. ° If knob does not pop up when released, stop and 5. Wait five (5) minutes to clear out any gas. If you then immediately call your service technician or gas supplier. ° If the pilot will not stay lit after several tries, turn the gas smell gas, @ STOPI Follow"B" in the safety information above on this label. If you don't smell gas, go to next step. This unit is equipped with a push button pilot igniter, which is used to light the pilot. Locate the igniter on the gas control. control knob clockwise f_ to "OFF" and call your service technician or gas supplier. SEE FIGURE "A". 11. Once the pilot flame is established replace the outer burner door. 12. At arms length away, turn gas control knob 7, Turn gas control knob counterclockwise _'_ to "PILOT", counterclockwise ('_ to "ON". SEE FIGURE "C". SEE FIGURE "B". 13. Set thermostat to desired setting. 8. The pilot is located on the right side of the burner. It can be located by looking through the glass view port while DANGER: Hotter water increases the risk of pressing the piezo igniter button several times. Look for a scald injury. Consuk the instruction manual spark at the pilot location, FIGURE "D'. before changing temperature. _to "OFF". Do not force. SEE FIGURE "A". 18

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

FOR YOUR SAFETY
READ BEFORE
UGHTING
WARNING:
If you
do
not
follow
these
instructions
exactly,
a fire
or
explosion
may
result
causing
property
damage,
personal
injury
or loss
of
life.
BEFORE
OPERATING:
ENTIRE
SYSTEM
MUST BE FILLED
W}TH WATER AND AIR PURGED
FROM ALL
LINES.
A.
This appliance
has a pilot which
is lit by a piezo
electric
gas ignition
system.
Do not open
the
inner door of the
appliance
and try to light the pilot by hand.
B.
BEFORE
UGHTING
smell all around
the applianoe
area
for gas. Be sure to smell
next to the floor because
some
gas is heavier
than air and will settle
on the floor.
WHAT
TO DO IFYOU
SMELL
GAS:
Do not try to light any appliance.
Do not touch
any electric
switch;
do not use any phone
in your building.
Immediately
call
your
gas supplier
from a neighbor's
phone.
Follow the gas supplier's
instructions.
C.
D.
If you
cannot
reach
your
gas
supplier,
call
the
fire
department.
Use only
your
hand
to push
in or turn the
gas control
knob. Never
use tools.
If the knob will not push in or turn
by hand,
don't
try
to repair
it, call a qualified
service
technician.
Force or attempted
repair may result in a fire
or explosion.
Do not
use this
appliance
if any part has
been
under
water. Immediately
contact
a qualified
installer or service
agency
to replace a flooded water heater.
Do not attempt
to repair the unit! It must be replaced!
UGHTING
iNSTRUCTiONS
1,
2.
3.
4,
5.
7,
8.
FmGURE "A"
"OFF
POSITION
HGURE
"g"
HGURE
"C"
"PILOT"
POSITION
"ON"
POSITRON
MAI_
8U_NER
/
GAS CONTROL
TOPKNOB
FIGURr: "D"
STOPI
Read the safety
information
above on this label.
Set the thermostat
to lowest
setting
(PILOT
LIGHTING).
Turn thermostat
dial fully clockwise
t_
until it stops.
Push the gas control knob down slightly and turn clockwise
f_
to"OFF",
SEE FIGURE
'W'.
NOTE:
Knob CANNOT
be turned
from "PILOT"
to "OFF"
unless
it is pushed
down
slightly.
Do not force.
Remove
the
outer
burner
door
located
below
the
gas
control.
Wait five
(5) minutes
to clear
out
any gas.
If you then
smell gas,
@
STOPI
Follow"B"
in the safety information
above on this label. If you don't smell gas, go to next step.
This unit is equipped
with a push button pilot igniter, which
is used
to light
the
pilot.
Locate
the
igniter
on
the gas
control.
Turn gas control
knob counterclockwise
_'_
to "PILOT",
SEE FIGURE
"B".
The pilot is located on the right side of the burner. It can be
located
by
looking
through
the
glass
view
port while
pressing
the piezo igniter button
several
times.
Look for a
spark at the pilot location,
FIGURE
"D'.
9.
Once
the pilot has been
found,
push the gas knob all the
way down.
Immediately
press the pilot igniter button rapidly
(4) to (5) times.
If the
pilot
will
not light,
repeat
step
(3)
through
(9).
10.
Continue
to hold the gas control
knob down for about
one
(!)
minute after the pilot is lit. Release
the gas control knob
and it will pop back up. Pilot should
remain
lit. If it goes out,
repeat
step (3) through
(9). It may take several
minutes
for
air to clear the lines before
the pilot will light.
°
If
knob
does
not
pop
up
when
released,
stop
and
immediately
call your service
technician
or gas supplier.
°
If the pilot will
not stay
lit after
several
tries,
turn the gas
control
knob clockwise
f_
to "OFF"
and call your service
technician
or gas supplier.
SEE FIGURE
"A".
11.
Once the pilot flame is established
replace the outer burner
door.
12.
At
arms
length
away,
turn
gas
control
knob
counterclockwise
('_
to "ON". SEE FIGURE
"C".
13.
Set thermostat
to desired setting.
DANGER:
Hotter
water
increases
the
risk
of
scald
injury.
Consuk
the
instruction
manual
before
changing
temperature.
_to
"OFF".
Do not force. SEE FIGURE
"A".
18