Kenwood TH-D74A User Manual - Page 95

STANDBY BEEP, REPEATER SCAN, REPEATER SCAN LOCKOUT, Group Lockout Setting, Individual Lockout Setting

Page 95 highlights

STANDBY BEEP This function is to notify with a beep sound that transmission has ended when a D-STAR signal is received. 1 Access Menu No. 645. ◆◆ If there is no more than one repeater registered in the repeater list, a repeater scan can not be performed. REPEATER SCAN LOCKOUT This function is to exclude and skip any repeater from the scan targets when D-STAR repeater lists are scanned. 2 Select [Off] or [On]. [Off]: Does not sound the standby beep. [On]: Sounds the standby beep. Note: ◆◆ The standby beep volume can be changed in Menu No. 915. ◆◆ When the reception sound is muted by the Callsign squelch/ Code squelch, the standby beep does not sound. REPEATER SCAN This function is to scan digital repeaters among the repeater list in DR mode. 1 Select [DR Scan] in the Digital Function Menu. DR Scan screen appears. Group Lockout Setting You can lock out all repeaters in a specific repeater group. 1 Access Menu No. 210. World region selection screen appears. 2 Select a World region and press [ENT]. Country region selection screen appears. 3 Select a Country region and press [ENT]. Group selection screen appears 4 Select a group to be skipped and press [A/B]. The lockout icon < >appears. 5 Press [PTT] to return to the frequency screen. 2 Select an item and press [A/B]. [FROM] and MHz dot flash and scan starts in the increasing direction of repeater numbers from the last repeater. The scan direction can be changed with [ ]/[ ] or [ENC] control. DR Scan Menu DR Scan Menu Operation Search for nearby repeaters (up to 20 Nearby Repeaters repeaters) that are near your station (within a range of 160 km (100 mi)) among D-STAR repeaters. World Region Search for the repeaters that are communicating among all D-STAR repeaters that belong to the World Region. Country Search for repeaters that are communicating among all D-STAR repeaters that belong to the Country. Group Search for repeaters that are communicating among all D-STAR repeaters that belong to the Group. 3 Press [ENT]. Scan stops. Note: ◆◆ Repeaters specified for Repeater Lockout can not be scanned. ◆◆ When scanning by [Nearby Repeaters], [Not Found] is displayed if there is no repeater that can be used within the range of 160 km (100 mi) from your station. ◆◆ [Nearby Repeaters] scan will not operate if GPS data is not received. ◆◆ Even if GPS is not positioning, the transceiver searches for nearby repeaters by the stored GPS data. Individual Lockout Setting You can lock out the specific repeaters in a repeater group. 1 Access Menu No. 210. World region selection screen appears. 2 Select a World region and press [ENT]. Country region selection screen appears. 3 Select a Country region and press [ENT]. Group selection screen appears 4 Select a group and press [ENT]. Repeater list selection screen appears. 5 Select a repeater and press [A/B]. The lockout icon < >appears. 6 Press [PTT] to return to the frequency screen. Note: ◆◆ [FROM] or [TO] setting screen of the transmission settings can be accessed even if repeaters are set to Repeater lockout. ◆◆ Even if repeaters set to Repeater lockout are registered to a memory channel, they will not be the memory channel lockout. 16-13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129

16-13
STANDBY BEEP
This function is to notify with a beep sound that transmission
has ended when a D-STAR signal is received.
1
Access Menu No. 645.
2
Select [Off] or [On].
[Off]:
Does not sound the standby beep.
[On]:
Sounds the standby beep.
Note:
The standby beep volume can be changed in Menu No. 915.
When the reception sound is muted by the Callsign squelch/
Code squelch, the standby beep does not sound.
REPEATER SCAN
This function is to scan digital repeaters among the repeater
list in DR mode.
1
Select [DR Scan] in the Digital Function Menu.
DR Scan screen appears.
2
Select an item and press
[A/B]
.
[FROM] and MHz dot flash and scan starts in the
increasing direction of repeater numbers from the last
repeater. The scan direction can be changed with
[
]/[
]
or
[ENC]
control.
DR Scan Menu
DR Scan Menu
Operation
Nearby Repeaters
Search for nearby repeaters (up to 20
repeaters) that are near your station (within
a range of 160 km
(100 mi)) among D-STAR
repeaters.
World Region
Search for the repeaters that are
communicating among all D-STAR repeaters
that belong to the World Region.
Country
Search for repeaters that are communicating
among all D-STAR repeaters that belong to
the Country.
Group
Search for repeaters that are communicating
among all D-STAR repeaters that belong to
the Group.
3
Press
[ENT]
.
Scan stops.
Note:
Repeaters specified for Repeater Lockout can not be scanned.
When scanning by [Nearby Repeaters], [Not Found] is
displayed if there is no repeater that can be used within the
range of 160 km (100 mi) from your station.
[Nearby Repeaters] scan will not operate if GPS data is not
received.
Even if GPS is not positioning, the transceiver searches for
nearby repeaters by the stored GPS data.
If there is no more than one repeater registered in the repeater
list, a repeater scan can not be performed.
REPEATER SCAN LOCKOUT
This function is to exclude and skip any repeater from the
scan targets when D-STAR repeater lists are scanned.
Group Lockout Setting
You can lock out all repeaters in a specific repeater group.
1
Access Menu No. 210.
World region selection screen appears.
2
Select a World region and press
[ENT]
.
Country region selection screen appears.
3
Select a Country region and press
[ENT]
.
Group selection screen appears
4
Select a group to be skipped and press
[A/B]
.
The lockout icon <
>appears.
5
Press
[PTT]
to return to the frequency screen.
Individual Lockout Setting
You can lock out the specific repeaters in a repeater group.
1
Access Menu No. 210.
World region selection screen appears.
2
Select a World region and press
[ENT]
.
Country region selection screen appears.
3
Select a Country region and press
[ENT]
.
Group selection screen appears
4
Select a group and press
[ENT]
.
Repeater list selection screen appears.
5
Select a repeater and press
[A/B]
.
The lockout icon <
>appears.
6
Press
[PTT]
to return to the frequency screen.
Note:
[FROM] or [TO] setting screen of the transmission settings can
be accessed even if repeaters are set to Repeater lockout.
Even if repeaters set to Repeater lockout are registered to a
memory channel, they will not be the memory channel lockout.