LG DLGX3701W Owners Manual - Page 24

Four-Wire Power Cord, green ground screw to the center screw of

Page 24 highlights

24 INSTALLATION Four-Wire Power Cord ••A 4-wire connection is required for all mobile and manufactured home installations, as well as all new construction after January 1, 1996. ••A UL-listed strain relief is required. ••Use a 30-amp, 240-volt, 4-wire, UL-listed power cord with #10 AWGminimum copper conductor and closed loop or forked terminals with upturned ends. 8 Tighten all screws securely. 9 Reinstall the terminal block access cover. Hot (Black) Neutral (White) Ground Screw Hot (Red) White Wire moved from Ground Screw Power Cord Ground Wire 1 Remove the terminal block access cover on the upper back of the dryer. 2 Install a UL-listed strain relief into the power cord through-hole. 3 Thread a 30-amp, 240-volt, 4-wire, UL-listed power cord with #10 AWG-minimum copper conductor through the strain relief. Terminal Block UL-Listed Strain Relief UL-Listed 4-Wire Power Cord 4 Transfer the dryer's ground wire from behind the green ground screw to the center screw of the terminal block. 5 Attach the two hot leads of the power cord to the outer terminal block screws. 6 Attach the white neutral wire to the center screw of the terminal block. 7 Attach the power cord ground wire to the green ground screw.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62

24
INSTALLATION
Four-Wire Power Cord
A 4-wire connection is required for
all mobile and manufactured home
installations, as well as all new
construction after January 1, 1996.
A UL-listed strain relief is required.
Use a 30-amp, 240-volt, 4-wire,
UL-listed power cord with #10 AWG-
minimum copper conductor and closed
loop or forked terminals with upturned
ends.
1
Remove the terminal block access cover on the
upper back of the dryer.
2
Install a UL-listed strain relief into the power
cord through-hole.
3
Thread a 30-amp, 240-volt, 4-wire, UL-listed
power cord with #10 AWG-minimum copper
conductor through the strain relief.
Terminal Block
UL-Listed Strain Relief
UL-Listed 4-Wire Power
Cord
4
Transfer the dryer’s ground wire from behind the
green ground screw to the center screw of the
terminal block.
5
Attach the two hot leads of the power cord to the
outer terminal block screws.
6
Attach the white neutral wire to the center screw
of the terminal block.
7
Attach the power cord ground wire to the green
ground screw.
8
Tighten all screws securely.
9
Reinstall the terminal block access cover.
Hot (Black)
Ground Screw
Power Cord Ground
Wire
White Wire moved from
Ground Screw
Hot (Red)
Neutral (White)