LG LAN121CNM Service Manual - Page 56
The phenomena in case of connecting error
View all LG LAN121CNM manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 56 highlights
Troubleshooting Guide The phenomena in case of connecting error INDOOR UNIT Connector Type Condition Phenomena CN-DC/DC Open and connecting error • The same as the phenomenon of Outdoor Unit. Blue Black Brown Red CN-MOTOR CN-UP/DOWN CN-DISP CN-TH Open Open Short between terminals Open Open Short between terminals ( and ) CN-TH2. Short between terminals ( and ) CN-TH1. • The indoor fan does not operate. • The operation indicator of Indoor unit blinks 8 times. • The up/down vane does not operate. • The up/down vane does not smoothly operate. • It does not operate with a remote controller. • The operation indicator blinks once. On for 0.5 second Off for 3 seconds • The compressor and the outdoor fan stop. • The indoor fan speed is low. • The operation indicator blinks once (on for 0.5 second, off for 3 seconds). • The compressor operates continuously regardless of the setting temperature and the variation of room temperature. • The operation indicator blinks once (on for 0.5 second, off for 3 seconds) • Continuous operation 56 Room Air Conditioner