Lantronix IntelliBox-I/O IntelliBox-I/O - Command Reference - Page 69

line 1 line:1 level commands, default flow control

Page 69 highlights

add clrscrn exit remove show show history write line 1 (line:1) level commands auto show statistics baud rate clear line counters clrscrn command mode always command mode echo serial string disable command mode echo serial string enable command mode serial string command mode serial string command mode serial string binary command mode signon message command mode signon message binary command mode wait time data bits 7 data bits 8 default baud rate default data bits default flow control default interface default parity default protocol default stop bits default xoff char default xon char exit flow control hardware flow control none flow control software interface rs232 interface rs485 full-duplex interface rs485 half-duplex 5: Commands and Levels Adds an entry to the IP filter table. Clears the screen. Returns to the config level. Removes an entry from the IP filter table. Displays the IP filter table. Displays the last 20 commands entered during the current CLI session. Stores the current configuration in permanent memory. Continuously displays line statistics. Sets the line speed. Sets the serial counters to zero. Clears the screen. Sets the current line to always be in command mode. Disables user-defined serial boot string to be echoed in the CLI. Enables user-defined serial boot string to be echoed in the CLI. Enables user to enter a custom string at boot time to enter command mode. Sets a string that can be entered at boot time to enter command mode. Sets a binary string that can be entered at boot time to enter command mode. Sets an ASCII sign-on message that is sent from the serial port when the Sets a binary sign-on message that is sent from the serial port when the Sets boot-up wait time for command mode serial string. Uses seven bits for data on the line. Uses eight bits for data on the line. Restores the default speed of 9600 bits per second. Restores the default of eight data bits. Restores the default of no flow control. Restores the default interface type to this line. Restores the default of no parity. Restores the default protocol on the line. Restores the default of one stop bit. Restores the default xoff character on this line. Restores the default xon character on this line. Exits to the enable level Uses hardware (RTS/CTS) flow control on the line. Does not provide flow control on the line. Uses software (xon/xoff characters) flow control on the line. Sets the line interface to RS232. Sets the line interface to RS485 in full-duplex mode. Sets the line interface to RS485 in half-duplex mode. IntelliBox-I/O 2100 Command Reference 69

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95

5: Commands and Levels
IntelliBox-I/O 2100 Command Reference
69
add
<ip address>
<subnet mask>
Adds an entry to the IP filter table.
clrscrn
Clears the screen.
exit
Returns to the config level.
remove
<ip address>
<subnet mask>
Removes an entry from the IP filter table.
show
Displays the IP filter table.
show history
Displays the last 20 commands entered during the current
CLI session.
write
Stores the current configuration in permanent memory.
line 1 (line:1) level commands
auto show statistics
Continuously displays line statistics.
baud rate
<bits per second>
Sets the line speed.
clear line counters
Sets the serial counters to zero.
clrscrn
Clears the screen.
command mode always
Sets the current line to always be in command mode.
command mode echo serial string disable
Disables user-defined serial boot string to be echoed in
the CLI.
command mode echo serial string enable
Enables user-defined serial boot string to be echoed in the
CLI.
command mode serial string
Enables user to enter a custom string at boot time to enter
command mode.
command mode serial string
<string>
Sets a string that can be entered at boot time to enter
command mode.
command mode serial string binary
<string>
Sets a binary string that can be entered at boot time to
enter command mode.
command mode signon message
<string>
Sets an ASCII sign-on message that is sent from the seri-
al port when the
command mode signon message binary
<string>
Sets a binary sign-on message that is sent from the serial
port when the
command mode wait time
<milliseconds>
Sets boot-up wait time for command mode serial string.
data bits 7
Uses seven bits for data on the line.
data bits 8
Uses eight bits for data on the line.
default baud rate
Restores the default speed of 9600 bits per second.
default data bits
Restores the default of eight data bits.
default flow control
Restores the default of no flow control.
default interface
Restores the default interface type to this line.
default parity
Restores the default of no parity.
default protocol
Restores the default protocol on the line.
default stop bits
Restores the default of one stop bit.
default xoff char
Restores the default xoff character on this line.
default xon char
Restores the default xon character on this line.
exit
Exits to the enable level
flow control hardware
Uses hardware (RTS/CTS) flow control on the line.
flow control none
Does not provide flow control on the line.
flow control software
Uses software (xon/xoff characters) flow control on the
line.
interface rs232
Sets the line interface to RS232.
interface rs485 full-duplex
Sets the line interface to RS485 in full-duplex mode.
interface rs485 half-duplex
Sets the line interface to RS485 in half-duplex mode.