Lantronix IntelliBox-I/O IntelliBox-I/O - Command Reference - Page 78

Sets the Modbus Response Timeout in milliseconds., Restores the default Modbus Response Timeout.

Page 78 highlights

case sensitive yes clrscrn default case sensitive default timeout milliseconds exit match no string no wildcard rss trace matches disable rss trace matches enable show show history string binary string set task timeout milliseconds wildcard write modbus (modbus) level commands additional port clrscrn default response timeout exit kill connection no additional port response timeout show show connections show history show statistics tcp server state disable tcp server state enable modem (tunnel-modem:2) level commands clrscrn connect string default incoming connection default response type IntelliBox-I/O 2100 Command Reference 5: Commands and Levels either a or A will Sets EventTrak monitoring to be case sensitive, requiring an exact match. Clears the screen. Sets the default EventTrak monitoring case sensitivity, which is not case Restores the default EventTrak monitoring timeout. Exits to the EventTrak level. Changes to the command level for EventTrak Match configuration. Removes the EventTrak monitoring match string. Removes the EventTrak wildcard character. Turns off RSS tracing of EventTrak string matches. Turns on RSS tracing to post each time EventTrak matches the string. Displays the current configuration. Displays the last 20 commands entered during the current CLI session. Sets the EventTrak monitoring match string allowing for binary characters. Sets the EventTrak monitoring match string. Changes to the command level for EventTrak Task configuration. Sets the EventTrak monitoring timeout milliseconds. Old data that might Sets the EventTrak monitoring wildcard character. Where it is placed in the Stores the current configuration in permanent memory. Sets an additional TCP server port. Clears the screen. Restores the default Modbus Response Timeout. Exits to the config level. Kills modbus connection selected by index from show connections. Removes the additional TCP server port. Sets the Modbus Response Timeout in milliseconds. Displays the current configuration. Displays connections. Displays the last 20 commands entered during the current CLI session. Displays statistics. Disables the Modbus TCP Server. Enables the Modbus TCP Server. Clears the screen. Sets the CONNECT string used in modem emulation. Default disables incoming network connections. Default uses text type responses. 78

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95

5: Commands and Levels
IntelliBox-I/O 2100 Command Reference
78
either a or A will
case sensitive yes
Sets EventTrak monitoring to be case sensitive, requiring
an exact match.
clrscrn
Clears the screen.
default case sensitive
Sets the default EventTrak monitoring case sensitivity,
which is not case
default timeout milliseconds
Restores the default EventTrak monitoring timeout.
exit
Exits to the EventTrak level.
match
<number>
Changes to the command level for EventTrak Match con-
figuration.
no string
Removes the EventTrak monitoring match string.
no wildcard
Removes the EventTrak wildcard character.
rss trace matches disable
Turns off RSS tracing of EventTrak string matches.
rss trace matches enable
Turns on RSS tracing to post each time EventTrak
matches the string.
show
Displays the current configuration.
show history
Displays the last 20 commands entered during the current
CLI session.
string binary
<binary>
Sets the EventTrak monitoring match string allowing for
binary characters.
string set
<text>
Sets the EventTrak monitoring match string.
task
<number>
Changes to the command level for EventTrak Task confi-
guration.
timeout milliseconds
<number>
Sets the EventTrak monitoring timeout milliseconds. Old
data that might
wildcard
<text>
Sets the EventTrak monitoring wildcard character. Where
it is placed in the
write
Stores the current configuration in permanent memory.
modbus (modbus) level commands
additional port
<number>
Sets an additional TCP server port.
clrscrn
Clears the screen.
default response timeout
Restores the default Modbus Response Timeout.
exit
Exits to the config level.
kill connection
<index>
Kills modbus connection selected by index from show
connections.
no additional port
Removes the additional TCP server port.
response timeout
<milliseconds>
Sets the Modbus Response Timeout in milliseconds.
show
Displays the current configuration.
show connections
Displays connections.
show history
Displays the last 20 commands entered during the current
CLI session.
show statistics
Displays statistics.
tcp server state disable
Disables the Modbus TCP Server.
tcp server state enable
Enables the Modbus TCP Server.
modem (tunnel-modem:2) level commands
clrscrn
Clears the screen.
connect string
<text>
Sets the CONNECT string used in modem emulation.
default incoming connection
Default disables incoming network connections.
default response type
Default uses text type responses.