Using Setup Mode for Configuration Figure 4-2. Setup Menu 4. Select an option on the menu by entering the number of the option in the Your choice ? field and pressing Enter. 5. To enter a value for a parameter, type the value and press Enter, or to confirm a current value, just press Enter. 6. When you are finished, save the new configurations (option 9). The unit reboots. Figure 4-3. Setup Mode Using the Serial Port To initially configure the unit through a serial connection: 1. Connect a console terminal or PC running a terminal emulation program to your unit's serial port. The default serial port settings are 9600 baud, 8 bits, no parity, 1 stop bit, no flow control. 2. To enter Setup Mode, reset the unit, either by pushing the red reset button, or by cycling the unit's power (power off and back on). The self-test will begin. You have one second to enter three lowercase x characters (xxx). Note: The easiest way is to hold down the x key at the terminal (or emulation) while resetting the unit. 4-2 Embedded Integration Kit User Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45

Using Setup Mode for Configuration
4-2
Embedded Integration Kit User Guide
Figure 4-2. Setup Menu
4.
Select an option on the menu by entering the number of the option in the
Your
choice
? field and pressing
Enter
.
5.
To enter a value for a parameter, type the value and press
Enter
,
or
to confirm a
current value, just press
Enter
.
6.
When you are finished, save the new configurations (option 9). The unit reboots.
Figure 4-3. Setup Mode
Using the Serial Port
To initially configure the unit through a serial connection:
1.
Connect a console terminal or PC running a terminal emulation program to your
unit's serial port. The default serial port settings are 9600 baud, 8 bits, no parity,
1 stop bit, no flow control.
2.
To enter Setup Mode, reset the unit, either by pushing the red reset button, or by
cycling the unit's power (power off and back on). The self-test will begin.
You
have one second
to enter three lowercase
x
characters (
xxx
).
Note:
The easiest way is to hold down the x key at the terminal (or
emulation) while resetting the unit.