Using Setup Mode for Configuration, Table 4-7. Manual Connection Address Example, Autostart,

Page 25 highlights

Using Setup Mode for Configuration For example, if the remote IP address already configured in the unit is 129.1.2.3, then an example command string would be C3/7. (This would connect to 129.1.2.3 and port 7.) You may also use a different ending for the connection string. For example, C50.1/23 would connect you to 129.1.50.1 and port 23. Table 4-7. Manual Connection Address Example Command String Result if remote IP is 129.1.2.3 and remote port is 1234 C121.2.4.5/1 Complete override; connection is started with host 121.2.4.5, port 1 C5 Connects to 129.1.2.5, port 1234 C28.10/12 Connects to 129.1.28.10, port 12 C0.0.0.0/0 Connect to 129.1.28.10, port 12; enter Monitor Mode Autostart (Automatic Connection) Hostlist If you enable autostart, the unit automatically connects to the remote IP address and remote port specified when the firmware starts. If you enable this option, the device server scrolls through the hostlist until it connects to a device listed in the hostlist table. Once it connects, the unit stops trying to connect to any others. If this connection fails, the unit continues to scroll through the table until it is able to connect to another IP in the hostlist. Hostlist supports a minimum of 1 and a maximum of 12 entries. Each entry contains the IP address and the port number. The hostlist is disabled for Manual Mode and for Modem Mode. The unit will not accept a data connection from a remote device when the host list option is enabled. Figure 4-7. Hostlist Option Baudrate (9600) ? I/F Mode (4C) ? Flow (00) ? Port No (10001) ? ConnectMode (C0) ?25 Hostlist : No Entry ! Change Hostlist ? (N) Y 01. IP address : (000) 172.(000) 19.(000) 0.(000) 1 (0) ?23 02. IP address : (000) 172.(000) 19.(000) 0.(000) 2 (0) ?3001 03. IP address : (000) 172.(000) 19.(000) 0.(000) 3 (0) ?10001 04. IP address : (000) .(000) .(000) .(000) Hostlist : 01. IP : 172.019.000.001 02. IP : 172.019.000.002 03. IP : 172.019.000.003 Port : 00023 Port : 03001 Port : 10001 Change Hostlist ? (N) N Port : Port : Port : 4-8 Embedded Integration Kit User Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45

Using Setup Mode for Configuration
4-8
Embedded Integration Kit User Guide
For example, if the remote IP address already configured in the
unit is 129.1.2.3, then an example command string would be
C3/7. (This would connect to 129.1.2.3 and port 7.) You may
also use a different ending for the connection string. For
example, C50.1/23 would connect you to 129.1.50.1 and port 23.
Table 4-7. Manual Connection Address Example
Command String
Result if remote IP is 129.1.2.3 and remote port is 1234
C121.2.4.5/1
Complete override; connection is started with host 121.2.4.5, port 1
C5
Connects to 129.1.2.5, port 1234
C28.10/12
Connects to 129.1.28.10, port 12
C0.0.0.0/0
Connect to 129.1.28.10, port 12; enter Monitor Mode
Autostart
(Automatic
Connection)
If you enable autostart, the unit automatically connects to the remote
IP address and remote port specified when the firmware starts.
Hostlist
If you enable this option, the device server scrolls through the hostlist
until it connects to a device listed in the hostlist table. Once it
connects, the unit stops trying to connect to any others. If this
connection fails, the unit continues to scroll through the table until it is
able to connect to another IP in the hostlist.
Hostlist supports a minimum of 1 and a maximum of 12 entries. Each
entry contains the IP address and the port number.
The hostlist is disabled for Manual Mode and for Modem Mode. The
unit will not accept a data connection from a remote device when the
host list option is enabled.
Figure 4-7. Hostlist Option
Baudrate (9600) ?
I/F Mode (4C) ?
Flow (00) ?
Port No (10001) ?
ConnectMode (C0) ?25
Hostlist :
No Entry !
Change Hostlist ? (N) Y
01. IP address : (000) 172.(000) 19.(000) 0.(000) 1
Port :
(0) ?23
02. IP address : (000) 172.(000) 19.(000) 0.(000) 2
Port :
(0) ?3001
03. IP address : (000) 172.(000) 19.(000) 0.(000) 3
Port :
(0) ?10001
04. IP address : (000) .(000) .(000) .(000)
Hostlist :
01. IP : 172.019.000.001
Port : 00023
02. IP : 172.019.000.002
Port : 03001
03. IP : 172.019.000.003
Port : 10001
Change Hostlist ? (N) N