Line (1 or 2) Status and Configuration, Table 7-7, Line Configuration Settings
View all Lantronix PremierWave 2050 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 51 highlights
7: Administration The line settings allow configuration of the serial line (ports). Line (1 or 2) Status and Configuration View-only status information on the Line 1 (or 2) - Statistics page displays line statistics including information on bytes, queued bytes, breaks, flow control, parity errors, framing errors, overrun errors, no Rx buffer errors, CTS input, RTS output, DSR input, and DTR output. See Table 7-5 for the line (1 or 2) settings that can be modified on the Line (1 or 2) - Configuration page. See Table 7-6 for the line (1 or 2) settings that can be established on the Line (1 or 2) Command Mode page. Line Settings Name Interface State Protocol Baud Rate Parity Data Bits Stop Bits Flow Control Xon Char Xoff Char Table 7-7 Line Configuration Settings Description Enter a name or short description for the line, if desired. By default, there is no name specified. A name that contains white space must be quoted. Set the interface type for the Line. The default is RS232. Choices are: RS232 RS485 Half-Duplex RS485 Full-Duplex Select to Enable or Disable the operational state of the Line. The default is Enabled. Set the operational protocol for the Line. The default is None. Choices are: None Set the Baud Rate (speed) of the Line. The default is 9600. Any set speed between 300 and 921600 may be selected: 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, 230400, 460800, 921600. When selecting a Custom baud rate, you may manually enter any value between 300 and 5000000921600. Note: Custom baud rates are not supported when a line is configured for Command Mode. Set the Parity of the Line. The default is None. Set the number of data bits for the Line. The default is 8. Set the number of stop bits for the Line. The default is 1. Set the flow control for the Line. The default is None. Note: This field becomes available if RS232 or RS485 Full-Duplex is selected under Interface above. Set Xon Char to be used when Flow Control is set to Software. Prefix decimal with \ or prefix hexadecimal with 0x or prefix a single control character . Note: This field becomes available for configuration when Software is selected under Flow Control. Set Xoff Char to be used when Flow Control is set to Software. Prefix decimal with \ or prefix hexadecimal with 0x or prefix a single control character . Note: This field becomes available for configuration when Software is selected under Flow Control. PremierWave® 2050 Enterprise Wi-Fi® IoT Module User Guide 51