Lenovo NetVista Hardware Maintenance Manual (HMM) for IBM NetVista 6826, 8317, - Page 70

Dual Async Adapter/A, Run Enhanced Diagnostics

Page 70 highlights

POST Error Code FRU/Action 962 Parallel port configuration error 1. Run Configuration 2. Parallel Adapter (if installed) 3. System Board 9XX 1. Printer 2. System Board 1047 1. 16-Bit AT™ Fast SCSI Adapter 107X Check SCSI terminator installation 1. Check SCSI terminator installation 2. SCSI Cable 3. SCSI Terminator 4. SCSI Device 5. SCSI Adapter 1101 1. Run Enhanced Diagnostics Serial connector error, possible system board failure 1101, 1102, 1106, 1108, 1109 1. System Board 2. Any Serial Device 1107 1. Communications Cable 2. System Board 1102 Card selected feedback error 1. Run Enhanced Diagnostics 1103 Port fails register check 1. Run Enhanced Diagnostics 2. System Board 1106 Serial option cannot be turned off 1. Run Enhanced Diagnostics 2. System Board 1107 1. Serial Device Cable 2. System Board 1110 Register test failed 1. Run Enhanced Diagnostics 2. System Board 1116 Interrupt error 1. Run Enhanced Diagnostics 1117 Failed baud rate test 1. Run Enhanced Diagnostics 1162 Serial port configuration error 1. Run Configuration 2. Serial Adapter (if installed) 3. System Board 11XX Not listed above 1. System Board 1201 1. System Board 2. Any Serial Device 1202, 1206, 1208, 1209, 12XX 1. Dual Async Adapter/A 2. System Board 3. Any Serial Device 64 Hardware Maintenance Manual

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152

POST Error Code
FRU/Action
962
Parallel port configuration error
1.
Run Configuration
2.
Parallel Adapter (if installed)
3.
System Board
9XX
1.
Printer
2.
System Board
1047
1.
16-Bit AT
Fast SCSI Adapter
107X
Check SCSI terminator installation
1.
Check SCSI terminator installation
2.
SCSI Cable
3.
SCSI Terminator
4.
SCSI Device
5.
SCSI Adapter
1101
Serial connector error, possible system board
failure
1.
Run Enhanced Diagnostics
1101, 1102, 1106, 1108, 1109
1.
System Board
2.
Any Serial Device
1107
1.
Communications Cable
2.
System Board
1102
Card selected feedback error
1.
Run Enhanced Diagnostics
1103
Port fails register check
1.
Run Enhanced Diagnostics
2.
System Board
1106
Serial option cannot be turned off
1.
Run Enhanced Diagnostics
2.
System Board
1107
1.
Serial Device Cable
2.
System Board
1110
Register test failed
1.
Run Enhanced Diagnostics
2.
System Board
1116
Interrupt error
1.
Run Enhanced Diagnostics
1117
Failed baud rate test
1.
Run Enhanced Diagnostics
1162
Serial port configuration error
1.
Run Configuration
2.
Serial Adapter
(if installed)
3.
System Board
11XX
Not listed above
1.
System Board
1201
1.
System Board
2.
Any Serial Device
1202, 1206, 1208, 1209, 12XX
1.
Dual Async Adapter/A
2.
System Board
3.
Any Serial Device
64