POST Error Code FRU/Action 6XX Not listed above 1. Diskette Drive 2. System Board 3. Riser card 4. External Drive Adapter 5. Diskette Drive Cable 6. Power Supply 762 Math coprocessor configuration error 1. Run Setup 2. Processor 3. System Board 7XX Not listed above 1. Processor 2. System Board 962 Parallel port configuration error 1. Run Configuration 2. Parallel Adapter (if installed) 3. System Board 9XX 1. Printer 2. System Board 1047 1. 16-Bit AT¬ Fast SCSI Adapter 107X Check SCSI terminator installation 1. Check SCSI terminator installation 2. SCSI Cable 3. SCSI Terminator 4. SCSI Device 5. SCSI Adapter 1101 1. Run diagnostics Serial connector error, possible system board failure 1101, 1102, 1106, 1108, 1109 1. System Board 2. Any Serial Device 1107 1. Communications Cable 2. System Board 1102 Card selected feedback error 1. Run diagnostics 1103 Port fails register check 1. Run diagnostics 2. System Board 1106 Serial option cannot be turned off 1. Run diagnostics 2. System Board 1107 1. Serial Device Cable 2. System Board 1110 Register test failed 1. Run diagnostics 2. System Board 1116 Interrupt error 1. Run diagnostics Chapter 6. Symptom-to-FRU Index 67

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152

POST Error Code
FRU/Action
6XX
Not listed above
1.
Diskette Drive
2.
System Board
3.
Riser card
4.
External Drive Adapter
5.
Diskette Drive Cable
6.
Power Supply
762
Math coprocessor configuration error
1.
Run Setup
2.
Processor
3.
System Board
7XX
Not listed above
1.
Processor
2.
System Board
962
Parallel port configuration error
1.
Run Configuration
2.
Parallel Adapter (if installed)
3.
System Board
9XX
1.
Printer
2.
System Board
1047
1.
16-Bit AT
¬
Fast SCSI Adapter
107X
Check SCSI terminator installation
1.
Check SCSI terminator installation
2.
SCSI Cable
3.
SCSI Terminator
4.
SCSI Device
5.
SCSI Adapter
1101
Serial connector error, possible system board
failure
1.
Run diagnostics
1101, 1102, 1106, 1108, 1109
1.
System Board
2.
Any Serial Device
1107
1.
Communications Cable
2.
System Board
1102
Card selected feedback error
1.
Run diagnostics
1103
Port fails register check
1.
Run diagnostics
2.
System Board
1106
Serial option cannot be turned off
1.
Run diagnostics
2.
System Board
1107
1.
Serial Device Cable
2.
System Board
1110
Register test failed
1.
Run diagnostics
2.
System Board
1116
Interrupt error
1.
Run diagnostics
Chapter 6. Symptom-to-FRU Index
67