Lenovo NetVista Hardware Maintenance Manual (HMM) for NetVista 2251, 6830, and - Page 80

Hard Disk Drive ESDI

Page 80 highlights

POST Error Code 10461 Drive format error 10462 Controller seek error 10464 Hard Drive read error 10467 Drive non-fatal seek error 10468 Drive fatal seek error 10469 Drive soft error count exceeded 10470, 10471, 10472 Controller wrap error 10473 Corrupt data. Low level format might be required 10480 10481 ESDI drive D seek error 10482 Drive select acknowledgement bad 106X1 10635 10651, 10660 106XX Not listed above 107XX 109XX Check the adapter cables FRU/Action 1. Run diagnostics 1. Run diagnostics 1. Run diagnostics 1. Run diagnostics 1. Run diagnostics 1. Run diagnostics 1. Run diagnostics Information only 1. Hard Disk Drive (ESDI) 2. Drive Cable 3. System Board 1. Run diagnostics 1. Run diagnostics 1. Check Configuration 2. Ethernet Adapter 1. Power-off computer, wait ten seconds then power-on the computer 2. Ethernet Adapter 1. Check Cables 2. Ethernet Adapter 1. Ethernet Adapter 1. 5.25-inch External Diskette Drive 2. 5.25-inch Diskette Drive Adapter/A 1. ActionMedia Adapter/A 2. System Board 3. Riser card 112XX This adapter does not have cache 72 Hardware Maintenance Manual 1. SCSI Adapter 2. Any SCSI Device 3. System Board 4. Riser card

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152

POST Error Code
FRU/Action
10461
Drive format error
1.
Run diagnostics
10462
Controller seek error
1.
Run diagnostics
10464
Hard Drive read error
1.
Run diagnostics
10467
Drive non-fatal seek error
1.
Run diagnostics
10468
Drive fatal seek error
1.
Run diagnostics
10469
Drive soft error count exceeded
1.
Run diagnostics
10470, 10471, 10472
Controller wrap error
1.
Run diagnostics
10473
Corrupt data. Low level format might be
required
Information only
10480
1.
Hard Disk Drive (ESDI)
2.
Drive Cable
3.
System Board
10481
ESDI drive D seek error
1.
Run diagnostics
10482
Drive select acknowledgement bad
1.
Run diagnostics
106X1
1.
Check Configuration
2.
Ethernet Adapter
10635
1.
Power-off computer, wait ten seconds
then power-on the computer
2.
Ethernet Adapter
10651, 10660
1.
Check Cables
2.
Ethernet Adapter
106XX
Not listed above
1.
Ethernet Adapter
107XX
1.
5.25-inch External
Diskette Drive
2.
5.25-inch Diskette
Drive Adapter/A
109XX
Check the adapter cables
1.
ActionMedia
Adapter/A
2.
System Board
3.
Riser card
112XX
This adapter does not have cache
1.
S
CSI Adapter
2.
Any SCSI Device
3.
System Board
4.
Riser card
72