Lenovo NetVista Hardware Maintenance Manual (HMM) for NetVista 2251, 6830, and - Page 76
Run Configuration. See, POST Error Code
View all Lenovo NetVista manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 76 highlights
POST Error Code 1117 Failed baud rate test 1162 Serial port configuration error 11XX Not listed above 1201 1202, 1206, 1208, 1209, 12XX 1207 13XX 1402 Printer not ready 1403 No paper error, or interrupt failure 1404 System board timeout failure 1405 Parallel adapter error 1406 Presence test error 14XX Not listed above. Check printer before replacing system board 15XX 1692 Boot sequence error 16XX 1762 Hard disk drive configuration error 1780 (Disk Drive 0) 1781 (Disk Drive 1) 1782 (Disk Drive 2) 1783 (Disk Drive 3) FRU/Action 1. Run diagnostics 1. Run Configuration 2. Serial Adapter (if installed) 3. System Board 1. System Board 1. System Board 2. Any Serial Device 1. Dual Async Adapter/A 2. System Board 3. Any Serial Device 1. Communications Cable 2. Dual Async Adapter/A 1. Game Adapter Information only Information only 1. Run diagnostics 1. Run diagnostics 1. Run diagnostics 1. Printer 2. System Board 1. SDLC Adapter 1. Run FDISK to ensure at least one active partition is set active 1. 36/38 Workstation Adapter 1. Run Configuration. (See "Setup Utility program" on page 8.) 1. See "Power supply" on page 35. 2. Hard Disk Drive 3. System Board 4. Riser card 5. Hard Disk Cable 6. Power Supply 68 Hardware Maintenance Manual