Lenovo ThinkPad 390E Hardware Maintenance Manual (March 1999): ThinkPad 390E o - Page 44

Checking the Operational Charging, Checking the Battery ASM

Page 44 highlights

Checking the Operational Charging: To check operational charging, use a discharged battery pack (Battery ASM) or a Battery ASM that has less than 50% of the total power remaining when installed in the computer. Perform operational charging. If the battery status indicator does not turn on, remove the Battery ASM and let it return to room temperature. Reinstall the Battery ASM. If the charge indicator still does not turn on, replace the Battery ASM. If the charge indicator still does not turn on, replace the DC-DC & BATT board, then the system board. Then reinstall the Battery ASM. If the reinstalled Battery ASM is not charged, go to the next section. Checking the Battery ASM: Battery ASM charging will not start until the Fuel-Gauge shows that less than 95% of the total power remains; with this condition, the Battery ASM can charge to 100% of its capacity. This protects the Battery ASM from being overcharged or having a shortened life. Do the following: 1. Power off the computer. 2. Remove the Battery ASM and measure the voltage between battery terminals 1(+) and 7(-). See the following figure: Note: Signal lines, not used in these steps, are used for communications between the system and the battery. 3. If the voltage is less than 10.6V (Li-Ion) or 9.6V (NiMH), the Battery ASM has been discharged, recharge the Battery ASM. If the voltage is still less than 10.6V (Li-Ion) or 9.6V (NiMH), replace the battery. 4. If the voltage is more than 10.6V (Li-Ion) or 9.6V (NiMH), measure the resistance between battery terminals 5 and 7. The resistance must be 390 ohm (Li-Ion) or 4 to 3K ohm. If the resistance is not correct, replace the Battery ASM. If the resistance is correct, replace the DC-DC & BATT board then the system board. 34 ThinkPad 390E

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130

Checking the Operational Charging:
To
check operational charging, use a discharged battery pack
(Battery ASM) or a Battery ASM that has less than 50% of
the total power remaining when installed in the computer.
Perform operational charging. If the battery status indicator
does not turn on, remove the Battery ASM and let it return
to room temperature. Reinstall the Battery ASM.
If the charge indicator still does not turn on, replace the
Battery ASM. If the charge indicator still does not turn on,
replace the DC-DC & BATT board, then the system board.
Then reinstall the Battery ASM. If the reinstalled Battery
ASM is not charged, go to the next section.
Checking the Battery ASM:
Battery ASM
charging will not start until the Fuel-Gauge shows that less
than 95% of the total power remains; with this condition,
the Battery ASM can charge to 100% of its capacity. This
protects the Battery ASM from being overcharged or
having a shortened life.
Do the following:
1.
Power off the computer.
2.
Remove the Battery ASM and measure the voltage
between battery terminals 1(+) and 7(-). See the fol-
lowing figure:
Note:
Signal lines, not used in these steps, are used
for communications between the system and
the battery.
3.
If the voltage is less than 10.6V (Li-Ion) or 9.6V
(NiMH), the Battery ASM has been discharged,
recharge the Battery ASM. If the voltage is still less
than 10.6V (Li-Ion) or 9.6V (NiMH), replace the
battery.
4.
If the voltage is more than 10.6V (Li-Ion) or 9.6V
(NiMH), measure the resistance between battery ter-
minals 5 and 7. The resistance must be 390 ohm
(Li-Ion) or 4 to 3K ohm. If the resistance is not
correct, replace the Battery ASM. If the resistance is
correct, replace the DC-DC & BATT board then the
system board.
34
ThinkPad 390E