LiftMaster CSW24VDC CSW24VDC Installation Manual - Page 37

ERROR CODES continued..., or OPEN - LiftMaster Plug-in Loop Detector only

Page 37 highlights

TROUBLESHOOTING ERROR CODES continued... Some errors are saved in the error code history and some are not. If an error is not saved it will briefly appear on the error code display as it occurs, then disappear. Error Code 31 34 35 36 37 38 40 41 42 43 44 45 46 47 50 53 54 60 61 62 63 64 65 Meaning Solution Control board has experienced an internal failure. Disconnect all power, wait 15 seconds, then reconnect power (reboot). If issue continues, replace control board. Absolute Position Encoder Error, not getting position information from encoder Check the operator cable connections, then reprogram the limits. Max-Run-Time Exceeded Error Check for an obstruction, then reprogram the limits. Product ID Error Was the control board just replaced? If so, erase limits, enter limit setup mode and set limits. If not, disconnect all power, wait 15 seconds, then reconnect power before changing product ID harness. Product ID Failure Unplug product ID harness then plug back in. Disconnect all power, wait 15 seconds, then reconnect power before replacing product ID harness. Hard Stop Limit Limit may be set too tightly against a non-resilient hard stop (re-adjust limit). Operator may be at end of travel (re-adjust mounting). Battery overvoltage Too much voltage on the battery. Check harness. Make sure you do NOT have a 24V battery on a 12V system. Battery overcurrent Possible short of the battery charge harness. Check harness. Make sure you do NOT have a 12V battery on a 24V system. No battery at boot up Check battery connections and installation. Replace batteries if depleted to less than 20V on a 24V system. Make sure you do NOT have a single 12V battery on a 24V system. Loop Error - Failure or missing exit loop (SHORT Check loop wiring throughout connection. May be a short in the loop, or OPEN - LiftMaster Plug-in Loop Detector only) or an open connection in the loop. Loop Error - Failure or missing shadow loop (SHORT or OPEN - LiftMaster Plug-in Loop Detector only) Check loop wiring throughout connection. May be a short in the loop, or an open connection in the loop. Loop Error - Failure or missing interrupt loop (SHORT or OPEN - LiftMaster Plug-in Loop Detector only) Check loop wiring throughout connection. May be a short in the loop, or an open connection in the loop. Wireless edge battery low Replace batteries in wireless edge. Battery shorted Check battery harness for short to chassis Run-Distance Error Gate unbalance detected. Make sure the gate is installed on a level surface and not on an excessive grade. Brownout occurred AC/DC board supply dipped below allowable level. Review power supply and wiring. If rebooting, ensure enough time for discharge of power to force a fresh boot. Wireless Second Operator Communication Error Check the second operator for power. If OFF, restore power and try to run the system. If powered, deactivate the wireless feature and then re-learn the second operator. Minimum number of monitored entrapment protection devices (one) not installed. Review monitored entrapment protection device connections. CLOSE EYE/INTERRUPT held more than 3 minutes Check CLOSE EYE/INTERRUPT input on main board; check for (main board) alignment or obstruction. CLOSE EDGE held more than 3 minutes (main board) Check CLOSE EDGE input on main board; check for alignment or obstruction. OPEN EYE/EDGE held more than 3 minutes (main Check OPEN EYE/EDGE input on main board; check for alignment or board) obstruction. CLOSE EYE/INTERRUPT held more than 3 minutes Check wired input on expansion board; check for alignment or (expansion board) obstruction. CLOSE EYE/EDGE held more than 3 minutes (expansion board) Check wired input on expansion board; check for alignment or obstruction. Saved NO YES YES YES YES NO YES YES YES YES YES YES YES YES YES YES YES NO YES YES YES YES YES 36

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56

36
ERROR CODES continued...
Some errors are saved in the error code history and some are not. If an error is not saved it will briefly appear on the error code display as it occurs,
then disappear.
TROUBLESHOOTING
Error Code
Meaning
Solution
Saved
31
Control board has experienced an internal failure.
Disconnect all power, wait 15 seconds, then reconnect power (reboot).
If issue continues, replace control board.
NO
34
Absolute Position Encoder Error, not getting
position information from encoder
Check the operator cable connections, then reprogram the limits.
YES
35
Max-Run-Time Exceeded Error
Check for an obstruction, then reprogram the limits.
YES
36
Product ID Error
Was the control board just replaced? If so, erase limits, enter limit
setup mode and set limits. If not, disconnect all power, wait 15
seconds, then reconnect power before changing product ID harness.
YES
37
Product ID Failure
Unplug product ID harness then plug back in. Disconnect all power,
wait 15 seconds, then reconnect power before replacing product ID
harness.
YES
38
Hard Stop Limit
Limit may be set too tightly against a non-resilient hard stop (re-adjust
limit). Operator may be at end of travel (re-adjust mounting).
NO
40
Battery overvoltage
Too much voltage on the battery. Check harness. Make sure you do
NOT have a 24V battery on a 12V system.
YES
41
Battery overcurrent
Possible short of the battery charge harness. Check harness. Make
sure you do NOT have a 12V battery on a 24V system.
YES
42
No battery at boot up
Check battery connections and installation. Replace batteries if
depleted to less than 20V on a 24V system. Make sure you do NOT
have a single 12V battery on a 24V system.
YES
43
Loop Error - Failure or missing exit loop (SHORT
or OPEN - LiftMaster Plug-in Loop Detector only)
Check loop wiring throughout connection. May be a short in the loop,
or an open connection in the loop.
YES
44
Loop Error - Failure or missing shadow loop
(SHORT or OPEN - LiftMaster Plug-in Loop
Detector only)
Check loop wiring throughout connection. May be a short in the loop,
or an open connection in the loop.
YES
45
Loop Error - Failure or missing interrupt loop
(SHORT or OPEN - LiftMaster Plug-in Loop
Detector only)
Check loop wiring throughout connection. May be a short in the loop,
or an open connection in the loop.
YES
46
Wireless edge battery low
Replace batteries in wireless edge.
YES
47
Battery shorted
Check battery harness for short to chassis
YES
50
Run-Distance Error
Gate unbalance detected. Make sure the gate is installed on a level
surface and not on an excessive grade.
YES
53
Brownout occurred
AC/DC board supply dipped below allowable level. Review power
supply and wiring. If rebooting, ensure enough time for discharge of
power to force a fresh boot.
YES
54
Wireless Second Operator Communication Error
Check the second operator for power. If OFF, restore power and try to
run the system. If powered, deactivate the wireless feature and then
re-learn the second operator.
YES
60
Minimum number of monitored entrapment
protection devices (one) not installed.
Review monitored entrapment protection device connections.
NO
61
CLOSE EYE/INTERRUPT held more than 3 minutes
(main board)
Check CLOSE EYE/INTERRUPT input on main board; check for
alignment or obstruction.
YES
62
CLOSE EDGE held more than 3 minutes (main
board)
Check CLOSE EDGE input on main board; check for alignment or
obstruction.
YES
63
OPEN EYE/EDGE held more than 3 minutes (main
board)
Check OPEN EYE/EDGE input on main board; check for alignment or
obstruction.
YES
64
CLOSE EYE/INTERRUPT held more than 3 minutes
(expansion board)
Check wired input on expansion board; check for alignment or
obstruction.
YES
65
CLOSE EYE/EDGE held more than 3 minutes
(expansion board)
Check wired input on expansion board; check for alignment or
obstruction.
YES