LiftMaster EL2000 EL25-KEYPAD PROGRAMMING Manual - Page 42
Add or Edit a Full Function Card: 81, Add a Group of Cards at Once: 82, Factory Settings, Full Access
View all LiftMaster EL2000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 42 highlights
Add or Edit a Full Function Card: 81 When adding a full function card, it will default as "Active". To deactivate a code, or deactivate on a specific time and date, see Activate or Deactivate Card on page 42. 1 Press Then 2 Enter Card Number (1-65534 [26 or 30-bit]). Then (#) 3 Enter Facility Code (0-63 [30-bit], 0-255 [26-bit]). Then (#) 4 Enter Card Type (26 or 30). Then (#) 5 Schedule for Door 1 (0-63). Then (#) 0=Full Restrictions 1=Full Access Example: 6 Schedule for Door 2 (0-63). Then (#) 0=Full Restrictions 1=Full Access 7 Schedule for Door 3 (0-63). Then (#) 0=Full Restrictions 1=Full Access 8 Schedule for Door 4 (0-63). Then (#) 0=Full Restrictions 1=Full Access Factory Settings All Doors = 1 Full Access Door 1 Door 2 Door 3 Door 4 Access Cards d Access Cards Ac 1 2 3 4 5 6 7 8 Adds card with number "12287", Facility Code "1", 30-bit Card Type, schedule "2", that opens door 1 ONLY NOTE: For new cards, if you don't add a Facility Code or Card Type, the system will add the defined default values. For details, see Default Facility Code or Default Card Type on page 43. NOTE: To replace a lost card first delete the lost card (Step 88 on page 42) and then add the new card to the unit's database (Step 81 on this page). NOTE: The new card uses the default settings for active and inactive values. To modify these settings use Step 87 on page 42. Add a Group of Cards at Once: 82 This feature allows you to enter a large number of cards into the system at one time. Individual cards from a group can be edited later. For example, you have 250 cards that you want to enter into the system so that every time someone needs a card, you won't have to program the system individually to enter a new card. 1 Press Then 7 Schedule for Door 1 (0 to 63). Then (#) 0=Full Restrictions 1=Full Access 2 Enter Card Number (1-65534 [26 or 30-bit]). 8 Schedule for Door 2 (0 to 63). Then (#) Then (#) 0=Full Restrictions 1=Full Access 3 Enter Ending Card Number (1-65534 [26 or 9 Schedule for Door 3 (0 to 63). Then (#) 30-bit]). Then (#) 0=Full Restrictions 1=Full Access 3 Enter Facility Code (0-63 [30-bit], 10 Schedule for Door 4 (0 to 63). Then (#) 0-255 [26-bit]). Then (#) 0=Full Restrictions 1=Full Access 3 Card Type (26 or 30). Then (#) 3 Activate (1) or Deactivate (0). Then (#) Factory Settings: All Doors = 1 Full Access Example: 1 2 3 4 5 6 7 8 9 10 Adds a inactive group of Cards that range between "21500" and "21600", default Facility Code, 30-bit Card Type, inactive, and valid at all doors. NOTES: • Group cards must be the same Card Type and have the same Facility Code. In addition, you may also activate the cards, add a schedule to one or more doors. These options must also be the same. • If you don't add a Facility Code or Card Type when adding a new card group, the system will add the defined default values. For details see Default Facility Code or Default Card Type on page 43. Page 41