LiftMaster EL2000 EL25-KEYPAD PROGRAMMING Manual - Page 42

Add or Edit a Full Function Card: 81, Add a Group of Cards at Once: 82, Factory Settings, Full Access

Page 42 highlights

Add or Edit a Full Function Card: 81 When adding a full function card, it will default as "Active". To deactivate a code, or deactivate on a specific time and date, see Activate or Deactivate Card on page 42. 1 Press Then 2 Enter Card Number (1-65534 [26 or 30-bit]). Then (#) 3 Enter Facility Code (0-63 [30-bit], 0-255 [26-bit]). Then (#) 4 Enter Card Type (26 or 30). Then (#) 5 Schedule for Door 1 (0-63). Then (#) 0=Full Restrictions 1=Full Access Example: 6 Schedule for Door 2 (0-63). Then (#) 0=Full Restrictions 1=Full Access 7 Schedule for Door 3 (0-63). Then (#) 0=Full Restrictions 1=Full Access 8 Schedule for Door 4 (0-63). Then (#) 0=Full Restrictions 1=Full Access Factory Settings All Doors = 1 Full Access Door 1 Door 2 Door 3 Door 4 Access Cards d Access Cards Ac 1 2 3 4 5 6 7 8 Adds card with number "12287", Facility Code "1", 30-bit Card Type, schedule "2", that opens door 1 ONLY NOTE: For new cards, if you don't add a Facility Code or Card Type, the system will add the defined default values. For details, see Default Facility Code or Default Card Type on page 43. NOTE: To replace a lost card first delete the lost card (Step 88 on page 42) and then add the new card to the unit's database (Step 81 on this page). NOTE: The new card uses the default settings for active and inactive values. To modify these settings use Step 87 on page 42. Add a Group of Cards at Once: 82 This feature allows you to enter a large number of cards into the system at one time. Individual cards from a group can be edited later. For example, you have 250 cards that you want to enter into the system so that every time someone needs a card, you won't have to program the system individually to enter a new card. 1 Press Then 7 Schedule for Door 1 (0 to 63). Then (#) 0=Full Restrictions 1=Full Access 2 Enter Card Number (1-65534 [26 or 30-bit]). 8 Schedule for Door 2 (0 to 63). Then (#) Then (#) 0=Full Restrictions 1=Full Access 3 Enter Ending Card Number (1-65534 [26 or 9 Schedule for Door 3 (0 to 63). Then (#) 30-bit]). Then (#) 0=Full Restrictions 1=Full Access 3 Enter Facility Code (0-63 [30-bit], 10 Schedule for Door 4 (0 to 63). Then (#) 0-255 [26-bit]). Then (#) 0=Full Restrictions 1=Full Access 3 Card Type (26 or 30). Then (#) 3 Activate (1) or Deactivate (0). Then (#) Factory Settings: All Doors = 1 Full Access Example: 1 2 3 4 5 6 7 8 9 10 Adds a inactive group of Cards that range between "21500" and "21600", default Facility Code, 30-bit Card Type, inactive, and valid at all doors. NOTES: • Group cards must be the same Card Type and have the same Facility Code. In addition, you may also activate the cards, add a schedule to one or more doors. These options must also be the same. • If you don't add a Facility Code or Card Type when adding a new card group, the system will add the defined default values. For details see Default Facility Code or Default Card Type on page 43. Page 41

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80

Page 41
Access Cards
Access Cards
Add a Group of Cards at Once:
1
Press
Then
2
Enter Card Number (1-65534 [26 or 30-bit]).
Then (#)
3
Enter Ending Card Number (1-65534 [26 or
30-bit]). Then (#)
3
Enter Facility Code (0-63 [30-bit],
0-255 [26-bit]). Then (#)
3
Card Type (26 or 30). Then (#)
3
Activate (
1
) or Deactivate (
0
). Then (#)
This feature allows you to enter a large number of cards into the system at one time. Individual
cards from a group can be edited later. For example, you have 250 cards that you want to enter
into the system so that every time someone needs a card, you won’t have to program the
system individually to enter a new card.
NOTES:
• Group cards must be the
same Card Type
and have the
same Facility Code
. In addition,
you may also activate the cards, add a schedule to one or more doors. These options must
also be the same.
• If you don’t add a Facility Code or Card Type when adding a new card group, the system will
add the defined default values. For details see Default Facility Code or Default Card Type on
page 43.
7
Schedule for Door 1 (0 to 63). Then (#)
0=Full Restrictions 1=Full Access
8
Schedule for Door 2 (0 to 63). Then (#)
0=Full Restrictions 1=Full Access
9
Schedule for Door 3 (0 to 63). Then (#)
0=Full Restrictions 1=Full Access
10
Schedule for Door 4 (0 to 63). Then (#)
0=Full Restrictions 1=Full Access
Factory Settings:
All Doors =
1 Full Access
Adds a inactive group of Cards that range between "21500" and "21600", default Facility Code,
30-bit Card Type, inactive, and valid at all doors.
c
A
d
Example:
1
2
3
4
5
6
7
8
9
10
Add or Edit a Full Function Card:
1
Press
Then
2
Enter Card Number (1-65534 [26 or 30-bit]).
Then (#)
3
Enter Facility Code (0-63 [30-bit],
0-255 [26-bit]). Then (#)
4
Enter Card Type (26 or 30). Then (#)
5
Schedule for Door 1 (0-63). Then (#)
0
=Full Restrictions
1
=Full Access
When adding a full function card, it will default as "
Active
". To deactivate a code, or deactivate
on a specific time and date, see
Activate or Deactivate Card
on page 42.
Example:
Door 2
Door 1
3
4
5
6
Door 3
7
Door 4
8
2
1
NOTE:
For new cards, if you don’t add a Facility Code or Card Type, the system will add the
defined default values. For details, see Default Facility Code or Default Card Type on page 43.
NOTE:
To replace a lost card first delete the lost card
(Step 88 on page 42) and then add the
new card
to the unit’s database (Step 81 on this page).
NOTE:
The new card uses the default settings for active and inactive values. To modify these
settings use Step 87 on page 42.
6
Schedule for Door 2 (0-63). Then (#)
0
=Full Restrictions
1
=Full Access
7
Schedule for Door 3 (0-63). Then (#)
0
=Full Restrictions
1
=Full Access
8
Schedule for Door 4 (0-63). Then (#)
0
=Full Restrictions
1
=Full Access
Factory
Settings
All Doors =
1 Full Access
Adds card with number "12287", Facility Code "1", 30-bit Card Type, schedule
"2", that opens door 1 ONLY
82
81