LiftMaster GH GH LOGIC 3 Manual - Page 13

Logic Ver. 3.0 1 Phase Wiring Diagram

Page 13 highlights

LOGIC (VER. 3.0) 1 PHASE WIRING DIAGRAM 115V MOTOR CONNECTION 230V MOTOR CONNECTION NOTE: Gray (GY) and purple (PU) motor wires are reversed for H and HJ right hand models and all GH and J models. CPS-L & CPS-LN4 Sensing Edge Hoist Interlock When Present TMR DEF SWITCH (YE) (BL) Maintenance Alert LED (RD) (WH) Open Close Stop OPEN CLOSE STOP 3-Button Station Open/Close Single Button Remove Jumper To Install External Door Interlock MAS 10 EYES 9 EDGE 8 OPEN 7 CLOSE 6 STOP 5 CMN 4 3 2 SBC 1 F1 D31 D7 D6 D5 D4 24V AC 14 24V AC 13 TIMER DEFEAT 12 CMN 11 C3Ø CLOSE D21 D2Ø D15 D23 P1Ø C17 C25 POWER D19 TIMER DEFEAT R8 D17 MAS D28 R31 U7 D8 D22 OPEN D1 EDGE EYES 4 C18 ENABLE TIMER J3ØØ 3 2 MRT MID TIMER J1 D25 X1 D27 D26 D24 Ø14LGØ657-A Ø14GPØ657-A P4 MOTOR DIRECTION D36 CLS SLS MID OLS 1 RADIO D16 R29 C11 D3Ø2 K3 E1 U1 P7 hot neutral ground L3 L2 L1 (BK) MOV MOV (BR) See Motor Connections (WH) 115 / 230 VOLT 1PH. POWER IN (WH) COM 120 120 / 240 VAC VAC (WH) NO COM C (YE) +24 VAC -24 VAC COIL (GY) (WH) COM OPEN L/S NO NC (RD) (PU) (WH) COM NO CLOSE L/S NC NOTE: Lock Sensor is provided on Models DJ and DH only, red wire from main harness connects to NC on Bypass L/S and to NO on Lock Sensor switch. White wires connect the COM on Bypass L/S and Lock Sensor switch to NC on Open L/S. COM BYPASS L/S (WH) (RD) NO NC (WH) LOCK NO SENSOR (see note at left) NC (RD) (YE) (WH) NC SAFETY L/S NO COM 13 RELAY A C77 C73 L1 L5 P6 RELAY B D35 T E 2 D 1 STOP D13 T S FSTS DIAG SBC PROG (B2 C2 D1 E2) S8 NON FAILSAFE D14 P1 D34 C54 C71 C78 ® C 2 B 2 FAILSAFE (YE) (OR) (WH) (YE) (PU) (WH) (RD) (GY) (YE) (RD) (WH) (PU) (YE) (OR) (GY) (WH) 0 B 1 4 8 2 6 (YE) (WH) (OR) (PU) (WH) (WH) (WH) (WH) (WH) 0 A 1 4 8 2 6 (YE) (PU) (BL) (GY) See Motor Connections (WH) (RD) (YE) (GY) (WH) (OR) (YE) 1 2 3 4 RPM Board R1 R2 R3 Radio

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

13
U1
POWER
TIMER
DEFEAT
MAS
4
MRT
1
RADIO
MID
2
TIMER
TIMER
ENABLE
T
TS
FSTS
E2
RELAY A
RELAY B
D1
DIAG
C2
B2
PROG
3
24V
AC
24V
AC
TIMER
DEFEAT
CMN
MAS
EYES
EDGE
OPEN
CLOSE
STOP
CMN
SBC
11
10
9
14
13
12
8
7
6
5
4
3
2
1
CLOSE
STOP
OPEN
EDGE
OLS
MID
SLS
MOTOR
DIRECTION
CLS
D25
D24
D26
D27
D36
C77
C73
C54
C78
L1
L5
P6
D35
S8
D16
P7
EYES
K3
P1
D34
F1
FAILSAFE
(
B2
C2
D1
E2
)
NON FAILSAFE
D23
D15
D1
D22
R8
J1
X1
E1
R29
C18
D8
U7
R31
D31
C3
Ø
D7
D6
D5
D4
C25
C17
C11
D3
Ø
2
P1
Ø
P4
Ø
14LG
Ø
657–A
Ø
14GP
Ø
657–A
J3
ØØ
D2
Ø
D21
D13
D14
D28
D17
D19
SBC
C71
®
Remove Jumper
To Install External
Door Interlock
3-Button
Station
Maintenance
Alert LED
(RD)
(WH)
Open
Close
Stop
Open/Close
Single Button
Sensing
Edge
CPS-L & CPS-LN4
Hoist Interlock
When Present
TMR DEF
SWITCH
MOV
MOV
(YE)
(BL)
(YE)
(OR)
(WH)
(YE)
(PU)
(WH)
(RD)
(GY)
(YE)
(RD)
(WH)
(PU)
(YE)
(OR)
(GY)
(OR) (PU)
(WH)
(WH)
(WH)
(WH)
(WH)
(PU)
(YE)
(WH)
(WH)
(WH)
(WH)
(YE)
115 / 230
VOLT 1PH.
POWER IN
hot
neutral
ground
(BK)
COM
120
VAC
120 / 240
VAC
+24 VAC
-24 VAC
See Motor
Connections
8
0
1
4
6
2
6
2
8
4
0
1
COIL
COM
NO
C
B
A
(WH)
(BL)
(GY)
(YE)
(BR)
(GY)
See Motor
Connections
NOTE:
Lock Sensor is provided on Models
DJ and DH only, red wire from main harness
connects to NC on Bypass L/S and to NO on
Lock Sensor switch. White wires connect the
COM on Bypass L/S and Lock Sensor switch to
NC on Open L/S.
OPEN
CLOSE
STOP
NOTE:
Gray (GY) and purple (PU) motor wires are reversed
for H and HJ right hand models and all GH and J models.
115V MOTOR CONNECTION
230V MOTOR CONNECTION
(WH)
(WH)
(WH)
(RD)
(PU)
(YE)
COM
NO
NC
NO
NC
COM
NO
NC
COM
OPEN
L/S
NO
NC
LOCK
SENSOR
(see note at left)
CLOSE
L/S
SAFETY
L/S
(WH)
(RD)
NO
NC
COM
BYPASS
L/S
(WH)
(RD)
(WH)
(RD)
(YE)
(GY)
(WH)
(OR)
(YE)
1
2
3
4
RPM Board
Radio
R1
R2
R3
L3
L2
L1
LOGIC (VER. 3.0) 1 PHASE WIRING DIAGRAM