LiftMaster GH GH LOGIC 3 Manual - Page 4
Operator Specifications - nema 4
View all LiftMaster GH manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 4 highlights
OPERATOR SPECIFICATIONS MOTOR TYPE Continuous Duty HORSEPOWER 1/2, 3/4, 1, 1-1/2, 2 and 3 HP SPEED 1725 RPM VOLTAGE 115/220/230V 1 Phase, 208/230/380/460/575V 3 Phase CURRENT See Motor Nameplate ELECTRICAL TRANSFORMER 24Vac Secondary CONTROL STATION NEMA 3-Button Station Open/Close/Stop w/LED WIRING TYPE C2 (Standard) Momentary contact to OPEN and STOP, constant pressure to CLOSE, plus wiring for sensing device to reverse and auxiliary devices to open and close with open override. See pages 16 and 17 for optional wiring types and operating modes. LIMIT ADJUST Linear driven, fully adjustable screw type cams MECHANICAL DRIVE REDUCTION 45:1 for 1/2, 3/4, and 1 HP 44:1 for 1-1/2, 2 42:1 for 3 HP OUTPUT SHAFT SPEED 38.3 for 1/2, 3/4, and 1 HP 39.2 for 1-1/2 and 2 HP 41.1 for 3 HP DOOR SPEED 4 - 10" per second depending on door BRAKE Solenoid actuated disc brake HOIST WHEEL Standard mounting on left or right side SAFETY DISCONNECT Floor level chain hoist with electrical interlock for manual door operation CLUTCH (Optional Adjustable torque limiter type SAFETY PHOTO EYES (Optional CPS-L): Through beam or retro reflective devices used to provide non-contact safety protection SAFETY EDGE (Optional): Electric or pneumatic sensing device attached to the bottom edge of door 4