LiftMaster LA412 LA412 Manual - Page 25

Reinstall cover., Secure operator and extension cables with watertight connector nut. - model

Page 25 highlights

WIRING » JUNCTION BOX (MODEL LA412-S ONLY) 6 Remove terminals from operator cable. Strip wires and twist like colored wires together with wire nuts. 6 Operator Cable Wire Nut Green Brown Brown Red Green White Yellow Blue White Yellow Blue Red Extension Cable 7 Put wires inside of junction box. 8 Secure operator and extension cables with watertight connector nut. 9 Reinstall cover. 24 Watertight Connector Nut 7 8 Watertight Connector Nut 9 Screws (4)

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44

24
Remove terminals from operator cable. Strip wires and twist like colored wires
together with wire nuts.
Wire Nut
Operator Cable
Extension Cable
Yellow
Blue
Red
Blue
Red
White
White
Brown
Green
Brown
Green
Yellow
Put wires inside of junction box.
Secure operator and extension cables with watertight connector nut.
Reinstall cover.
Screws (4)
WIRING
ยป JUNCTION BOX (MODEL LA412-S ONLY)
6
6
7
8
9
7
8
9
Watertight Connector Nut
Watertight Connector Nut