LiftMaster Readers User Guide - Page 5
PROGRAMMING, Configure the KPR2000.
View all LiftMaster Readers manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 5 highlights
PROGRAMMING 4 Configure the KPR2000. Change the configure settings according to your application (optional). Multiple configuration settings can be changed at one time: enter program mode, change desired settings, then exit program mode. SET MASTER CODE The 6 digit Master Code is used to prevent unauthorized access to the system. To interface with the KPR2000, the manager will need a Master Code (factory default code: 888888). We highly recommend immediate update and recording of your Master Code. Programming Step 1. Enter Program Mode 2. Update Master Code 3. Exit Program Mode Keystroke Combination ✱ (Master Code) # 0 (New Code) # (New Code) # ✱ SET ACCESS CONFIGURATION There are 3 types of access configurations for the KPR2000: • Card or PIN (Default): The User must present a valid Wiegand Card to the KPR2000 or enter their PIN code followed by the # key, in order to be granted access. • Card Only: The User must present a valid Wiegand Card to the KPR2000 in order to be granted access. The facility code and the ID number are both read and validated as one block of Wiegand data. • Card + PIN: The User must first present a valid Wiegand Card to the KPR2000 and then enter their PIN code followed by the # key, in order to be granted access. Programming Step 1. Enter Program Mode 2. Card Only OR 2. Card + PIN OR 2. Card or PIN 3. Exit Program Mode Keystroke Combination ✱ (Master Code) # 3 0 # 3 1 # 3 2 # ✱ SET RELAY CONFIGURATION The relay configuration sets the behavior of the output relay on activation. Programming Step 1. Enter Program Mode 2. Pulse Mode OR 2. Latch Mode 3. Exit Program Mode Keystroke Combination ✱ (Master Code) # 4 (1-99) # The relay time is 1-99 seconds (default is 5 seconds) 4 0 # Sets the relay to ON/OFF latch mode ✱ SET WIEGAND INPUT/OUTPUT OPTIONS The KPR2000 offers input and output for industry standard Wiegand devices (refer to Specifications). Default is HID 26 bit. SET DOOR OPEN TOO LONG (DOTL) ALARM This setting requires an external sensor input. The alarm output timing can be set from 1-3 minutes (default is 1 minute). Factory default is OFF. Programming Step 1. Enter Program Mode 2. DOTL Alarm OFF OR 2. DOTL Alarm ON OR 2. DOTL Output Timing 3. Exit Program Mode Keystroke Combination ✱ (Master Code) # 6 0 # 6 1 # (Alarm sounds for 1 minute) 9 (1-3) # ✱ SET STRIKE-OUT ALARM The strike-out alarm will engage after 10 failed card/PIN attempts. Factory default is OFF. The strike-out alarm can be set to deny access for 10 minutes after engaging or it can be set to disengage only after entering a valid master code or card. Programming Step 1. Enter Program Mode 2. Strike-Out OFF OR 2. Strike-Out ON OR 2. Strike-Out ON 3. Exit Program Mode Keystroke Combination ✱ (Master Code) # 7 0 # (Factory default) 7 1 # Access will be denied for 10 minutes 7 2 # Enter Master Code or Valid Card to silence ✱ SET AUDIBLE AND VISUAL RESPONSE Factory default is ON. Programming Step Keystroke Combination 1. Enter Program Mode ✱ (Master Code) # 2. Control Backlight OR 2. Control LED OR 2. Control Sounds 3. Exit Program Mode ON = 7 5 # ON = 7 7 # ON = 7 9 # ✱ OFF = 7 4 # OFF = 7 6 # OFF = 7 8 # Programming Step 1. Enter Program Mode 2. Set Wiegand Format 3. Exit Program Mode Keystroke Combination ✱ (Master Code) # 9 (Bit Format) # Bit Format = Valid 2 digit format (example: 26 or 30) ✱ 5