MSI H87M User Guide - Page 104

RST Synchronization (optional)

Page 104 highlights

Appendix B RST Synchronization (optional) If you are using Maximized mode as the Acceleration mode, the data on the hard disk is not always synchronized with the data in the SSD cache. In some situations, you may want to manually sync the disks for avoiding data loss. Follow these steps to sync manually. 1. Reboot system, during the Power-On Self Test (POST) press, press and keys simultaneously to enter the Intel Rapid Storage Technology Option ROM. 2. Select option 5 "Acceleration Options" and press key. The following screen appears. Name DISK PORT 0 [ ACCELERATION OPTIONS ] Type Non-RAID Disk Capacity Mode 153.4GB Maximized Status No Sync [ HELP ] Press 's' to synchronize data from the cache device to the Accelerated Disk/Volume. Press 'r' to remove the Disk/Volume Acceleration. WARNING: IT IS RECOMMENDED THAT YOU [ERFORM A SYNCHRONIZATION BEFORE REMOVING ACCELERATION. [ ↑↓] - Select [ESC] - Previous Menu 3. Press to synchronize data. [ SYNCHRONIZATION VERIFICATION ] SYNCHRONIZING THE DA5T. A MEAxYit TAKE SEVERAL MINUTES. D[O DNIOSTK I/NVTOELRURMUEPINTFTOHREMPARTOIOCNES]S! Are you sure you want to synchronize data to "DISK PORT 0"? (Y/N): 4. When prompted, press to confirm. Name DISK PORT 0 [ ACCELERATION OPTIONS ] Type Non-RAID Disk Capacity Mode 153.4GB Maximized Status In Sync 5. Once synchronization is complete, the status will change to In Sync. Intel RAID B-14

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104

Appendix B
B-14
Intel RAID
RST Synchronization (optional)
If you are using Maximized mode as the Acceleration mode, the data on the hard disk
is not always synchronized with the data in the SSD cache. In some situations, you
may want to manually sync the disks for avoiding data loss.
Follow these steps to sync manually.
Reboot system, during the Power-On Self Test (POST) press, press <Ctrl> and
<I> keys simultaneously to enter the Intel Rapid Storage Technology Option ROM.
Select option 5 “Acceleration Options” and press <Enter> key. The following
screen appears.
1.
2.
[
]
ACCELERATION OPTIONS
[
]
HELP
Name
Press 's' to synchronize data from the cache device to
the Accelerated Disk/Volume.
Press 'r' to remove the Disk/Volume Acceleration.
WARNING:
IT IS RECOMMENDED THAT YOU [ERFORM A SYNCHRONIZATION
BEFORE REMOVING ACCELERATION.
[ ↑↓] - Select
[ESC] - Previous Menu
Type
Capacity
Status
DISK PORT 0
Non-RAID Disk
153.4GB
Mode
Maximized
No Sync
Press <S> to synchronize data.
3.
[
]
ACCELERATION OPTIONS
Name
Type
Capacity
Status
DISK PORT 0
Non-RAID Disk
153.4GB
Mode
Maximized
In Sync
SYNCHRONIZING THE DATA MAY TAKE SEVERAL MINUTES.
DO NOT INTERRUPT THE PROCESS!
[
]
SYNCHRONIZATION VERIFICATION
Are you sure you want to synchronize data to
"DISK PORT 0"? (Y/N):
When prompted, press <Y> to confirm.
4.
Once synchronization is complete, the status will change to In Sync.
5.