Electrical Connection - U.S.A. Only, Power Supply Cord, Direct Wire

Page 11 highlights

Electrical Connection - U.S.A. Only Power Supply Cord WARNING 3. Depending on your model, remove plastic tag holding three 10-32 hex nuts from the middle post of the terminal block. Electrical Shock Hazard Disconnect power before servicing. Use a new 40 amp power supply cord. Plug into a grounded outlet. Failure to follow these instructions can result in death, fire, or electrical shock. Direct Wire WARNING OR Remove the top 10-32 hex nut from each of the 3 terminal blocks and set aside. 4. Add strain relief. Style 1: Power supply cord strain relief � Remove the knockout for the power supply cord. � Assemble a UL listed strain relief in the opening. Electrical Shock Hazard Disconnect power before servicing. Use 8 gauge copper or 6 gauge aluminum wire. Electrically ground range. Failure to follow these instructions can result in death, fire, or electrical shock. 1. Disconnect power. 2. Remove the terminal block cover screws located on the back of the range. Pull cover down and toward you to remove cover from range. A. UL listed strain relief � Tighten strain relief screw against the power supply cord. A. Two mounting tabs each side B. Terminal block cover C. Hex-head screws 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57

11
Electrical Connection - U.S.A. Only
Power Supply Cord
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use a new 40 amp power supply cord.
Plug into a grounded outlet.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Direct Wire
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge copper or 6 gauge aluminum wire.
Electrically ground range.
Failure to follow these instructions can result in death,
fire, or electrical shock.
1.
Disconnect power.
2.
Remove the terminal block cover screws located on the back
of the range. Pull cover down and toward you to remove cover
from range.
A.
Two mounting tabs each side
B.
Terminal block cover
C.
Hex-head screws
3.
Depending on your model, remove plastic tag holding three
10-32 hex nuts from the middle post of the terminal block.
OR
Remove the top 10-32 hex nut from each of the 3 terminal
blocks and set aside.
4.
Add strain relief.
Style 1: Power supply cord strain relief
Remove the knockout for the power supply cord.
Assemble a UL listed strain relief in the opening.
A.
UL listed strain relief
Tighten strain relief screw against the power supply cord.