Meade ETX125 Instruction Manual - Page 56
Appendix D:changing The, Lnt Module Battery
View all Meade ETX125 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 56 highlights
Adjustment screws Fig. 54: The LNT Module, with adjustment screws and Atomic Time Update port visible. Spring Atomic Time Update Port Bottom Adjustment screw Side Adjustment screw hole Fig. 55: Interior side view of LNT module. bottom Adjustment screw hole Cover Battery Side Adjustment screw hole Spring Fig. 56 Interior top view of SmartFinder unit. APPENDIX D:CHANGING THE LNT MODULE BATTERY The LNT Module uses a lithium coin CR2023 battery that will last about 5 years and is installed with the original LNT Module assembly. After you replace the battery, you will need to recalibrate the telescope's sensors and reset the time and date. You will need a new battery. Also, you may use Meade's optional Atomic Time Update Module, although this is not necessary. To replace the battery: 1. Remove the top adjustment screw cap/long bolt from the LNT Module. See Fig. 54. 2. Remove the side adjustment screw cap/long bolt from the LNT Module. Take note that there are two springs inside the LNT. One spring is on the bottom of the unit. The second spring is on the side of the unit. One long bolt passes through the side spring and the other long bolt passes through the bottom spring. Set the springs aside as you will need to replace it later in this assembly. See Fig. 55 and 56. Important Note: Note there is some wiring inside the LNT Module. Be careful not to pull on the wiring. If it is necessary to move the wiring aside, do so carefully. 3. Carefully lift the top section of the unit from the bottom section. Do not remove the bottom section or disassemble the rest of the unit. 4. Remove the old battery. Note the spring. 5. Insert the new (user-supplied) battery. Take care to orient the battery so that the side with the battery markings is facing the top. 6. Replace the bottom spring in place and the LNT Module cover. 7. Replace the bottom bolt and tighten the cap to a firm feel. 8. Hold the side spring in place with your fingers and slide the spring between between the top and bottom sections. The spring should line up with the mounting holes for the side long bolt. Slide the long bolt through the side hole, then through the spring and finally through the bottom of the LNT Module and tighten to a firm feel. 9. Next you will need to recalibrate the LNT Module sensors. Select Calibrate Sensors from the Setup: Telescope menu. A scrolling message displays. 10. The message prompts you to place the telescope in the home position: • Loosen the telescope's vertical lock (6, Fig. 1B). This will allow you to move the telescope's optical tube up and down. • Level the tripod head. See Step #3g, page 12. Level the optical tube by lining up 0° on the Dec setting circle (16, Fig. 1a) with the Dec pointer (the small molded triangle under the setting circle). • Retighten the vertical lock (6, Fig. 1b) to a firm feel only. • Unlock the horizontal lock (9, Fig. 1a). This will allow you to rotate the telescope tube and fork arm assembly. • Grasp the telescope by a fork arm and rotate the telescope counterclockwise until it stops. • Re-lock the Horizontal lock (9, Fig. 1). 11. Press ENTER. The telescope will automatically find North, detect level and the tilt of you telescope, and calibrate the sensors. 12. Next, follow the instructions included with the Atomic Time Update Module optional accessory to reset the clock. OR Enter the date and time manually using the Date and Time options in the Setup menu. 56