NaceCare TTV678 TTV678 Owners Manual (External Charger) - Page 18
Changing the Floor Tool Blades
View all NaceCare TTV678 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 18 highlights
Changing the Floor Tool Blades ! ALWAYS ENSURE THAT THE BATTERY IS DISCONNECTED PRIOR TO ANY MAINTENANCE ! The TTV range is provided with the aluminium floor-tool shown. The Floor Tool Fig.32 Fig.33 To clean the floor-tool, remove securing-pin and disconnect the lifting strap and remove the floor-tool securing pin pull-free the floor-tool from the rear of the machine. Rinse the floor-tool assembly with clean water and refit. Fig.34 Fig.35 Periodically the floor-tool blades should be examined and checked for wear and damage. The blade removal is easy. Simply start by removing the four retaining pins (see Fig.33), turn the floor-tool over and separate the blade carrier from the body (see Fig.34).Peel away the blades from their locating lugs (see Fig.35) and examine or renew as required. Replacement is a reversal of the removal process. Floor-tool overview 1. Floor-tool main body 1 2. Rear blade 3. Blade carrier 2 4. Front blade (slotted) 5. Retaining pins x 4 3 Note: 4 5 Floor Tool adjusters are factory set for optimal performance. The blades are designed to be reversible, thus extending their useful working life. 18