NaceCare TTV678 TTV678 Owners Manual (External Charger) - Page 18

Changing the Floor Tool Blades

Page 18 highlights

Changing the Floor Tool Blades ! ALWAYS ENSURE THAT THE BATTERY IS DISCONNECTED PRIOR TO ANY MAINTENANCE ! The TTV range is provided with the aluminium floor-tool shown. The Floor Tool Fig.32 Fig.33 To clean the floor-tool, remove securing-pin and disconnect the lifting strap and remove the floor-tool securing pin pull-free the floor-tool from the rear of the machine. Rinse the floor-tool assembly with clean water and refit. Fig.34 Fig.35 Periodically the floor-tool blades should be examined and checked for wear and damage. The blade removal is easy. Simply start by removing the four retaining pins (see Fig.33), turn the floor-tool over and separate the blade carrier from the body (see Fig.34).Peel away the blades from their locating lugs (see Fig.35) and examine or renew as required. Replacement is a reversal of the removal process. Floor-tool overview 1. Floor-tool main body 1 2. Rear blade 3. Blade carrier 2 4. Front blade (slotted) 5. Retaining pins x 4 3 Note: 4 5 Floor Tool adjusters are factory set for optimal performance. The blades are designed to be reversible, thus extending their useful working life. 18

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

18
Fig.32
Fig.34
Fig.35
Fig.33
!
!
ALWAYS ENSURE THAT THE BATTERY IS DISCONNECTED PRIOR TO ANY
MAINTENANCE
Note:
Floor Tool adjusters are factory set for optimal performance.
The blades are designed to be reversible, thus extending their useful working life.
Changing the Floor Tool Blades
To clean the floor-tool, remove securing-pin and disconnect the lifting strap and remove the floor-tool securing pin
pull-free the floor-tool from the rear of the machine.
Rinse the floor-tool assembly with clean water and refit.
Periodically the floor-tool blades should be examined and checked for wear and damage.
The blade removal is easy. Simply start by removing the four retaining pins (see Fig.33), turn the floor-tool over and
separate the blade carrier from the body (see Fig.34).Peel away the blades from their locating lugs (see Fig.35) and
examine or renew as required.
Replacement is a reversal of the removal process.
Floor-tool overview
1. Floor-tool main body
2. Rear blade
3. Blade carrier
4. Front blade (slotted)
5. Retaining pins x 4
1
2
3
4
5
The TTV range is provided with the aluminium floor-tool shown.
The Floor Tool