Panasonic AV-HS410 Operating Instructions Basic - Page 37
°C to 40 °C 32 °F to 104 °F, TALLY/GPI 1
View all Panasonic AV-HS410 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 37 highlights
4. Specifications Control I/O Other Ambient operating temperature Humidity Dimensions (W H D) Mass COM Used to control an external device RS-422 control connector Communication format (selected using a menu) pp Mode: 1 (default setting) Baud rate : 9600 bps Character length : 8 bit Parity : None Stop bit : 1 bit Flow control : None pp Mode: 2 Baud rate : 38400 bps Character length : 8 bit Parity : Odd Stop bit : 1 bit Flow control : None pp Mode: 3 Baud rate : 38400 bps Character length : 8 bit Parity : None Stop bit : 1 bit Flow control : None TALLY/GPI 1 TALLY/GPI 2 Input: 8 inputs, general-purpose, photocoupler sensing Output: 19 outputs; selected from R/G tally, general-purpose Alarm: 1 output, open collector output (negative logic) BOOT switch [SV/NM (service/normal)] (for maintenance purposes) Normally, this switch is used as the "NM" position. 0 °C to 40 °C (32 °F to 104 °F) D-sub, 9-pin, female D-sub, 15-pin, female (2) 10 % to 90 % (no condensation) 440 mm 158 mm 361 mm (17-5/16 inches 6-7/32 inches 14-7/32 inches) [excluding protrusions] Approx. 6.2 kg (13.669 lb) [excluding accessory parts when no options have been installed] Approx. 6.6 kg (14.550 lb) [excluding accessory parts when all the possible options have been installed] 37