Clock Settings Information Acquisition, 4. Priority Mode Acquisition
View all Panasonic AW-HE42 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 47 highlights
5.3. Clock Settings Information Acquisition Method Access level : GET : Live CGI item name URL Clock settings information acquisition /cgi-bin/get_date _time Parameter name The response data is as shown below. display = 0/1 date_year = Numeric value date_month = Numeric value date_day = Numeric value date_hour = Numeric value date_min = Numeric value date_sec = Numeric value timezone = Numeric value (1 to 74) summer_time = 0/1/2 start_month = Numeric value start_week = Numeric value (1 to 5) start_dotw = Numeric value (0 to 6) start_hour = (0 to 23) end_month = Numeric value end_week = Numeric value (1 to 5) end_dotw = Numeric value (0 to 6) end_hour = Numeric value (0 to 23) is_summer_time = 0/1 (0: OFF, 1: ON) Parameter value Description 5.4. Priority Mode Acquisition Method Access level : GET : Live CGI item name URL Priority mode acquisition /cgi-bin/get_priori ty_mode Parameter name Parameter value Description The response data is as shown below. priority_mode = xxx * For details on the value notified by xxx, see the parameters of set_priority_mode. Integrated Camera Interface Specifications / Supplement for Web Control 46