【Update notification receive end sequence】 The update notification receive end command is sent from the terminal which has received the update notifications. "204 No Content" is returned from the camera which received the command. PC(ROP) Camera http://192.168.0.10/cgi-bin/event?connect=stop&my_port=31004&uid=0 204 No Content The receiving of the update notifications at PC is ended ③ Registered number of update notifications You can query the number of external devices (RP remote controller etc.) connected to the camera with the following command. The number of connected device increases with the procedure to start receiving update notifications and decreases the procedure to start receiving update notifications. The number of connected device also decreases when it can not communicate with the device. Number of terminals which can receive update notifications at the same time: 5 When the remote camera controller is connected, it is counted as one unit. example) When the IP address of the camera is "192.168.0.10" and you want to request registered number. http://192.168.0.10/cgi-bin/man_session?command=get PC(ROP) Camera http://192.168.0.10/cgi-bin/man_session?command=get 200 OK "Event session:1" © Panasonic Corporation 2020 All Rights Reserved. 12