Panasonic AW-UE100 IPSerial Control Interface Specifications - Page 52
Data4]Preset Speed Table
![]() |
View all Panasonic AW-UE100 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 52 highlights
Command name Category Command Data value Control #APS[Data1][Data2][Data 3][Data4] [Data1] 0000h 8000h FFFFh Setting [Data1]Pan Position CCW Limit Center CW Limit Response aPS[Data1][Data2][Data 3][Data4] P/T Absolute Position Control with Speed [Data2] 0000h 8000h FFFFh [Data2]Tilt Position UP Limit Center - DOWN Limit Request - [Data3] 00h 1Dh [Data3]Preset Speed 1 30 Response - [Data4] 0 1 2 [Data4]Preset Speed Table SLOW MID FAST P/T Relative Position Control with Speed Control #RPS[Data1][Data2][Dat a3][Data4] Response rPS[Data1][Data2][Data 3][Data4] Request - Response - [Data1] 0000h 8000h FFFFh [Data2] 0000h 8000h FFFFh [Data3] 00h 1Dh [Data4] 0 1 2 [Data1]Pan Position CCW Limit Center CW Limit [Data2]Tilt Position UP Limit Center - DOWN Limit [Data3]Preset Speed 1 30 [Data4]Preset Speed Table SLOW MID FAST Comand type ptz ptz Update notification - - camdata.html Usage example / Remarks http://192.168.0.10/cgi- bin/aw_ptz?cmd=%23APS800080001D0&res=1 - http://192.168.0.10/cgibin/aw_ptz?cmd=%23RPS800080001D0&res=1 - © Panasonic Corporation 2020 All Rights Reserved. 52
![](/manual_guide/products/panasonic-awue100-ipserial-control-interface-specifications-48b1887/52.png)