3.Command type There are two types of external interface command: Pan/Tilt control commands and camera control command. 3-1.Pan/Tilt control command This interface controls the pan tilt head. Starts with # (0x23), and ends with [CR](0x0d) example)Pan stop command # P 5 0 [CR] 0x23 0x50 0x35 0x30 0x0D ※[CR] is not required for IP communication Commands which command type is "ptz"(in chapter 9) are for Pan/Tilt control commands 3-2.Camera control command This interface is for the camera lens control and image/color adjustments. Starts with [STX] (0x02), and ends with [ETX] (0x03) ":" letter is required before [Data] for camera Control commands. example)Auto Focus setting [STX] O A F : 1 [ETX] 0x02 0x4F 0x41 0x46 0x3A 0x31 0x03 ※[STX] and [ETX] are not required for IP communication © Panasonic Corporation 2020 All Rights Reserved. 5