I/F Remote connector I/F REMOTE, Power indicator, DC 12 V input connector DC 12V IN, Cable clamp
View all Panasonic AWE860 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 13 highlights
< I/F Remote connector (I/F REMOTE) Input terminal dedicated to control signals from the optional remote control box (RCB) (WV-CB700A, etc.) and the RCU (WV-RC700A, WV-RC550, etc.) and the camera pan/tilt unit (AW-PH400, etc.). • WV-CB700A is connected through the optional RCB cable (AW-CA50T10/AW-CA50B10). • WV-RC700A/WV-RC550 is connected through the optional RCU cable (AW-CA50A26). • AW-PH400 is connected through the optional camera control cable (AW-CA50T8). = Power indicator Red LED lamp lights to indicate that the specified DC power is supplied to the camera. > DC 12 V input connector (DC 12V IN) 12 V DC is supplied through the optional DC power supply cable (AW-CA4T1). (Recommended AC adapter: AW-PS505) ? Cable clamp Clamp the DC power supply cable connected to the DC 12 V input connector to prevent it from slipping out. @ G/L input connector (G/L IN) Signals synchronized with the reference signal are to be supplied to this connector when the camera is to be synchronized with the reference signal BB. A Optional card slot Slot for inserting an optional card. For details, refer to the manual for optional cards. Cautions 1. Connect this to a DC 12 V class 2 power supply only. 2. To prevent fire or shock, the UL listed wire VW-1, style 1007 should be used as for the cable for DC 12 V input connector. -13-