Panasonic TY-TP50P10S Operating Instructions - Page 43

Checking Your USB Host Controllers ]

Page 43 highlights

[Checking Your USB Host Controllers ]  ㊍ Select [Control Panel] → [System] to open the Properties window and open the Device Manager window by clicking on [Device Manager] on the [Hardware] tab. (Example)  ㊎ Click on the "+" left of "Universal Serial Bus controllers". (A list of USB controllers opens.) • The USB controllers with the text "Host Controller" are host controllers. A USB bandwidth error warns that the host controller does not have enough bandwidth. • A USB 2.0 hub usually has one host controller, therefore only one touch panel can be connected to a USB 2.0 hub. Error Messages [Checking Host Controller Bandwidth] You can check which host controller the touch panel is connected to.  ㊍ Select [Control Panel] → [System] to open the Properties window and open the Device Manager window by clicking on [Device Manager] on the [Hardware] tab.  ㊎ Click on the "+" left of "Universal Serial Bus controllers". (A list of USB controllers opens.)  ㊏ Select a USB controller with the text "Host Controller" and right click on it to open the Properties window.  ㊐ Open the "Advanced" tab. Troubleshooting If a USB device by the name of "Panasonic Touch Panel Unit" appears in the "Advanced" tab, the touch panel is connected to that host controller. If a USB bandwidth error occurs, disconnect the USB cable connected to the touch panel, reconnect it, check which host controller it is connected to and connect it to another host controller. • After disconnecting and reconnecting the USB cable, the host controller bandwidth indication does not update until the "Refresh" button on the "Advanced" tab is clicked on. 43

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

43
Troubleshooting
[Checking Your USB Host Controllers ]
Select [Control Panel]
[System] to open the
Properties window and open the Device Manager
window by clicking on [Device Manager] on the
[Hardware] tab.
Click on the “+” left of “Universal Serial Bus
controllers”. (A list of USB controllers opens.)
The USB controllers with the text “Host Controller”
are host controllers.
A USB bandwidth error warns that the host
controller does not have enough bandwidth.
A USB 2.0 hub usually has one host controller,
therefore only one touch panel can be connected
to a USB 2.0 hub.
Error Messages
[Checking Host Controller Bandwidth]
You can check which host controller the touch panel is connected to.
Select [Control Panel]
[System] to open the Properties
window and open the Device Manager window by
clicking on [Device Manager] on the [Hardware] tab.
Click on the “+” left of “Universal Serial Bus controllers”.
(A list of USB controllers opens.)
Select a USB controller with the text “Host Controller”
and right click on it to open the Properties window.
Open the “Advanced” tab.
If a USB device by the name of “Panasonic Touch Panel Unit” appears in the “Advanced” tab, the touch panel
is connected to that host controller.
If a USB bandwidth error occurs, disconnect the USB cable connected to the touch panel, reconnect it, check
which host controller it is connected to and connect it to another host controller.
After disconnecting and reconnecting the USB cable, the host controller bandwidth indication does not update
until the “Refresh” button on the “Advanced” tab is clicked on.
(Example)