Panasonic WVSF332 WVSF332 User Guide - Page 14

Precautions for Installation

Page 14 highlights

Precautions for Installation Installation work shall be performed in accordance with the technology standard of the electric installation. This camera is designed to be used indoors. This product is not operable outdoors. Do not expose this camera to direct sunlight for hours and do not install the product near a heater or an air conditioner. Otherwise, it may cause deformation, discoloration and malfunction. Keep this camera away from water and moisture. Installing place Do not place this product in the following places: • Locations where it may get wet from rain or water splash • Locations where a chemical agent is used such as a swimming pool • Locations subject to humidity, dust, steam and oil smoke • Locations in a specific environment where a solvent or a flammable atmosphere exists • Locations where a radiation, an X-ray, a strong radio wave or a strong magnetic field is generated • Locations where corrosive gas is produced, Locations where it may be damaged by briny air such as seashores • Locations where the temperature is not within -10 °C to +50 °C {14 °F to 122 °F}. • Locations subject to vibrations (This product is not designed for on-vehicle use.) • Locations subject to condensation as the result of severe changes in temperature (In case of installing the camera in such locations, the dome cover may become foggy or condensation may be caused on the cover.) Be sure to remove this product if it is not in use. Shielded (STP) LAN cables must be used with this unit to ensure compliance with EMC standards. * * PAL models only Before installation • The camera mount bracket described on page 19 shall be used to mount the camera. • When this camera and camera mount bracket are mounted on a ceiling or a wall, use the screws described on page 19. The screws to be used are not provided. Prepare the screws according to the material, structure, strength and other factors of the mounting area and the total weight of objects to be mounted. • Ensure that the mounting surface, anchor and screws are sufficiently strong. • Do not mount this product on a plaster board or a wooden section because they are too weak. If this product is unavoidably mounted on such a section, the section shall be sufficiently reinforced or use an optional ceiling mount bracket (WV-Q105). Screw tightening • The screws and bolts must be tightened with an appropriate tightening torque according to the material and strength of the installation area. • Do not use an impact driver. Use of an impact driver may damage the screws or cause tightening excessively. • When a screw is tightened, make the screw at a right angle to the surface. After tightening the screws or bolts, perform visual check to ensure tightening is enough and there is no backlash. 14

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44

14
Precautions for Installation
Installation work shall be performed in accordance with the technology standard of the
electric installation.
This camera is designed to be used
indoors.
This product is not operable outdoors.
Do not expose this camera to direct sunlight for
hours and do not install the product near a
heater or an air conditioner. Otherwise, it may
cause deformation, discoloration and malfunc-
tion. Keep this camera away from water and
moisture.
Installing place
Do not place this product in the following plac-
es:
• Locations where it may get wet from rain
or water splash
• Locations where a chemical agent is used
such as a swimming pool
• Locations subject to humidity, dust, steam
and oil smoke
• Locations in a specific environment where
a solvent or a flammable atmosphere
exists
• Locations where a radiation, an X-ray, a
strong radio wave or a strong magnetic
field is generated
• Locations
where
corrosive
gas
is
pro
-
duced, Locations where it may be dam-
aged by briny air such as seashores
• Locations where the temperature is not
within –10 °C to +50 °C {14 °F to 122 °F}.
• Locations subject to vibrations (This prod
-
uct is not designed for on-vehicle use.)
• Locations subject to condensation as the
result of severe changes in temperature
(In case of installing the camera in such
locations, the dome cover may become
foggy or condensation may be caused on
the cover.)
Be sure to remove this product if it is not
in use.
Shielded (STP) LAN cables must be used
with this unit to ensure compliance with
EMC standards. *
* PAL models only
Before installation
• The camera mount bracket described on
page 19 shall be used to mount the cam-
era.
• When
this
camera
and
camera
mount
bracket are mounted on a ceiling or a wall,
use the screws described on page 19. The
screws to be used are not provided.
Prepare the screws according to the mate-
rial, structure, strength and other factors of
the mounting area and the total weight of
objects to be mounted.
• Ensure that the mounting surface, anchor
and screws are sufficiently strong.
• Do not mount this product on a plaster
board or a wooden section because they
are too weak. If this product is unavoidably
mounted on such a section, the section
shall be sufficiently reinforced or use an
optional ceiling mount bracket (WV-Q105).
Screw tightening
• The screws and bolts must be tightened
with an appropriate tightening torque
according to the material and strength of
the installation area.
• Do not use an impact driver. Use of an
impact driver may damage the screws or
cause tightening excessively.
• When
a
screw
is
tightened,
make
the
screw at a right angle to the surface. After
tightening the screws or bolts, perform
visual check to ensure tightening is enough
and there is no backlash.