Page 16 highlights
CLD-V2800 Level III • Chapter Two 3) The Serial Interface The Signal Level The signal level for the RS-232C is ± 12v. The Data type Parity bit : Data length : Stop bit : No parity. 8 bits. 1 bit. 1 START + 8 DATA + 1 STOP 0 1 START Figure 2-E D0 D1 D2 D3 D4 D5 D6 D7 STOP The Transmission speed 9600, 4800, 2400, or 1200 baud can be selected by using Dip Switches 1 and 2 on the back of the player: The Factory default setting is 4800 BAUD. BAUD 9600 4800 2400 1200 SW1 SW2 UP DOWN UP DOWN UP UP DOWN DOWN NOTE: A BAUD rate of 4800 or 1200 can also be set by sending a Level III command to Set Register C. See page 3-42 for details. 2-4 TP 120 v. 1.0 • 10/95 CLD-V2800 Level III User's Manual
3) The Serial Interface
The Signal Level
The signal level for the RS-232C is
±
12v.
The Data type
Parity bit
:
No parity.
Data length
:
8 bits.
Stop bit
:
1 bit.
The Transmission speed
9600, 4800, 2400, or 1200 baud can be selected by using Dip Switches 1 and 2 on
the back of the player: The Factory default setting is 4800 BAUD.
NOTE:
A BAUD rate of 4800 or 1200 can also be set by sending a Level III
command to Set Register C.
See page 3-42 for details.
CLD-V2800 Level III
•
Chapter Two
2-4
TP 120
v. 1.0
• 10/95
CLD-V2800 Level III User’s Manual
0
1
START
STOP
D0
D1
D2
D3
D4
D5
D6
D7
1 START + 8 DATA + 1 STOP
Figure 2-E
BAUD
SW1
SW2
9600
UP
UP
4800
DOWN
UP
2400
UP
DOWN
1200
DOWN
DOWN