Chapter Three • CLD-V2800 Level III 4) Timing The timing from the receipt of a command to the return of the status value is as follows: • T1 is the time from the receipt of at the end of the command string to the start of command execution, and is within a maximum of 20 ms. • T2 is the command execution time, and is at least 14 ms. T2 (before the ) increases depending on the type of command. • The minimum processing time for any command (total of T1 and T2) is 14 ms. Timing Diagram P L T1 TxD T1 ≤ 20 ms Figure 3-G T2 Execution T2 ≤ 14 ms R 3-10 TP 120 v. 1.0 • 10/95 CLD-V2800 Level III User's Manual
4)
Timing
The timing from the receipt of a command to the return of the status value is
as follows:
•
T1 is the time from the receipt of <C/R> at the end of the command string to
the start of command execution, and is within a maximum of 20 ms.
•
T2 is the command execution time, and is at least 14 ms.
T2 (before the <C/R>) increases depending on the type of command.
•
The minimum processing time for any command (total of T1 and T2) is 14 ms.
Chapter Three
•
CLD-V2800 Level III
Figure 3-G
Timing Diagram
P
L
<CR>
<CR>
R
TxD
T1
T2
Execution
3-10
TP 120
v. 1.0
• 10/95
CLD-V2800 Level III User’s Manual
T1
≤
20 ms
T2
≤
14 ms