ALARM OUTPUT Brown
UPC - 012562500638
View all Pioneer DEH-P77DH manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 11 highlights
ENGLISH ALARM OUTPUT (Brown) The brown lead provides a +12 V, constant or pulsed output while alarm is sounding. This lead has a maximum current capability of 500 mA and can be used to trigger a relay to sound a siren, horn or flash lights. 7 Recommended Wiring: 30 amp relay (sold separately) required to operate siren, horn or lights. • Connect Brown wire to one side of relay coil. • Connect ground to other side of coil. For sirens, horns or lights requiring +12 V trigger • Connect normally open pin to fused, constant +12 V source. For horns or lights requiring ground trigger • Connect normally open pin to ground. This product ESPAÑOL DEUTSCH FRANÇAIS ITALIANO NEDERLANDS Blue/Brown (refer to "STARTER CUT-OFF".) White/Orange (refer to "DOOR LOCK".) White/Red (refer to "ALARM SENSOR".) Brown RELAY (sold separately) White/Yellow (refer to "DOOR SWITCH".) 30 A Fuse (sold separately) CONTROL ≠+ 30 A BATT OUTPUT GND Car battery Horn/Siren, etc. Fig. 6 10