Rheem P-M406 Operating Instructions - Page 15

Outdoor Stack Kit Includes

Page 15 highlights

INDOOR HEATER INSTALLATION The heater is also design-certified for indoor installation when equipped with the approved drafthood. For Canada, indoor installation is restricted to an enclosure that is not occupied and does not directly communicate with an occupied area. Refer to the latest edition of CAN/CSA-B149 for specific requirements. Locate heater as close as is practical to a chimney or gas vent. Heater must always be vented to the outside. See Vent Piping section (pg. 18-19) for details. Minimum allowable space is shown on the nameplate. WARNING: Indoor heaters require a drafthood that must be connected to a vent pipe and properly vented to the outside. Failure to follow this procedure can cause fire or fatal carbon monoxide poisoning. OUTDOOR STACK / INDOOR STACK NOTE: The outdoor and indoor stacks are optional equipment and do not come standard with the heater. OUTDOOR STACK KIT INCLUDES: (1) Drafthood, painted (1) Adapter plate (3) Mounting brackets (clips) (1) Top panel cover (2) 1-foot sections of metal tape (3) Screws (1) Instructions Clips INDOOR STACK KIT INCLUDES: (1) Drafthood, unpainted (1) Adapter plate (3) Mounting brackets (clips) (3) Screws (1) Instructions Clips Model 206A/207A 266A/267A 336A/337A 406A/407A OUTDOOR STACK Part No. 009834 009835 009836 009837 INDOOR STACK Part No. 009838 009839 009840 009841 ** REFER TO INSTALLATION INSTRUCTIONS INSIDE BOX FOR INSTRUCTIONS ON HOW TO INSTALL OUTDOOR/INDOOR STACK. 15

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56

15
WARNING:
Indoor heaters require a drafthood that must be connected to a vent pipe and properly vented to
the outside. Failure to follow this procedure can cause fire or fatal carbon monoxide poisoning.
INDOOR HEATER INSTALLATION
The heater is also design-certified for indoor installation when equipped with the approved drafthood.
For Canada
, indoor installation is restricted to an enclosure that is not occupied and does not directly commu-
nicate with an occupied area. Refer to the latest edition of CAN/CSA-B149 for specific requirements. Locate
heater as close as is practical to a chimney or gas vent. Heater must always be vented to the outside. See Vent
Piping section (pg. 18-19) for details. Minimum allowable space is shown on the nameplate.
OUTDOOR STACK / INDOOR STACK
NOTE:
The outdoor and indoor stacks are optional equipment and do not come standard with the heater.
OUTDOOR STACK KIT INCLUDES:
(1) Drafthood, painted
(1) Adapter plate
(3) Mounting brackets (clips)
(1) Top panel cover
(2) 1-foot sections of metal tape
(3) Screws
(1) Instructions
Clips
INDOOR STACK KIT INCLUDES:
(1) Drafthood, unpainted
(1) Adapter plate
(3) Mounting brackets (clips)
(3) Screws
(1) Instructions
Clips
**REFER
TO
INSTALLATION
INSTRUCTIONS
INSIDE BOX FOR INSTRUCTIONS ON HOW TO
INSTALL OUTDOOR/INDOOR STACK.
OUTDOOR
STACK
INDOOR STACK
Model
Part No.
Part No.
206A/207A
266A/267A
336A/337A
406A/407A
009834
009835
009836
009837
009838
009839
009840
009841