RP 330 Pressing Tool Troubleshooting SYMPTOM POSSIBLE REASONS SOLUTION Tool will not turn ON when ON/OFF button on display panel is pressed. Electric cord damaged. Battery is completely discharged or battery has failed or power cord not properly inserted into outlet. Battery not properly inserted into handle of tool. Tool turns OFF either when trigger is depressed or in the middle of a press cycle. Red LED glows. Battery is too low. Tool or battery is too cold or too hot. Inspect the cord and replace if necessary. Insert fully charged battery/recharge dead battery or unplug and replug power cord. Check to assure battery is fully inserted. Insert fully charged battery/recharge dead battery. Bring tool and battery to correct operating range between 15°F (-10°C) to 122°F (50°C) by allowing the tool to sit in a conditioned room. NOTE! Fitting must be repressed if tool stops in the middle of a press cycle. Failure to do so may result in a leaking fitting. Yellow LED blinks repeatedly as long as tool is turned ON and tool functions properly. Scheduled maintenance/recalibration is required after 30,000 presses. Contact Ridge Tool Company, Technical Service Department at (800) 519-3456 for nearest Authorized Service outlet. Yellow LED glows continuously and tool will not begin press cycle when trigger switch is depressed. Scheduled maintenance/recalibration is mandatory after 32,000 presses. Tool is "locked" and will not function until tool is serviced. Contact Ridge Tool Company, Technical Service Department at (800) 519-3456 for nearest Authorized Service outlet. Red LED blinks repeatedly and tool will not begin press cycle when trigger switch is depressed. Accessory mounting pin not fully closed. Insert accessory mounting pin to the fully closed position. Yellow LED glows when Tool malfunction detected. tool is turned ON. Unplug and replug power cord or remove and reinsert fully charged battery. Be sure to repress fitting. If LED's continue to glow, contact Ridge Tool Company, Technical Service Department at (800) 519-3456 for nearest Authorized Service outlet. Jaws are locked onto fitting. Press was not successfully completed. Push pressure release valve to remove jaws from fitting. Inspect and repress fitting. The pressed connections produced are not complete. Used wrong jaw set for the tube size or material. The tool was not square to the tube. Jaw contour was not aligned with the fitting contour. Tool is in need of repair. Install the correct jaw set. Redo the joint with new fitting and new tube. Make sure that the tool is square to the tube. Redo the joint with new tube and new fitting. Make sure the jaw contour is aligned with the fitting contour. Contact Ridge Tool Company, Technical Service Department at (800) 519-3456 for nearest Authorized Service outlet. Ridge Tool Company 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43

Ridge Tool Company
11
RP 330 Pressing Tool
SYMPTOM
POSSIBLE REASONS
SOLUTION
Tool will not turn ON
when ON/OFF button on
display panel is pressed.
Tool turns OFF either
when trigger is de-
pressed or in the middle
of a press cycle. Red
LED glows.
Yellow LED blinks
repeatedly as long as
tool is turned ON and
tool functions properly.
Yellow LED glows con-
tinuously and tool will
not begin press cycle
when trigger switch is
depressed.
Red LED blinks repeated-
ly and tool will not begin
press cycle when trigger
switch is depressed.
Yellow LED glows when
tool is turned ON.
Jaws are locked onto
fitting.
The pressed connections
produced are not com-
plete.
Troubleshooting
Electric cord damaged.
Battery is completely discharged or battery has
failed or power cord not properly inserted into
outlet.
Battery not properly inserted into handle of tool.
Battery is too low.
Tool or battery is too cold or too hot.
Scheduled maintenance/recalibration is required
after 30,000 presses.
Scheduled maintenance/recalibration is manda-
tory after 32,000 presses. Tool is “locked” and
will not function until tool is serviced.
Accessory mounting pin not fully closed.
Tool malfunction detected.
Press was not successfully completed.
Used wrong jaw set for the tube size or material.
The tool was not square to the tube.
Jaw contour was not aligned with the fitting contour.
Tool is in need of repair.
Inspect the cord and replace if necessary.
Insert fully charged battery/recharge dead battery
or unplug and replug power cord.
Check to assure battery is fully inserted.
Insert fully charged battery/recharge dead battery.
Bring tool and battery to correct operating range
between 15°F (-10°C) to 122°F (50°C) by allow-
ing the tool to sit in a conditioned room.
NOTE!
Fitting must be repressed if tool stops
in the middle of a press cycle. Failure
to do so may result in a leaking fitting.
Contact Ridge Tool Company, Technical Service
Department at (800) 519-3456 for nearest
Authorized Service outlet.
Contact Ridge Tool Company, Technical Service
Department at (800) 519-3456 for nearest
Authorized Service outlet.
Insert accessory mounting pin to the fully closed
position.
Unplug and replug power cord or remove and rein-
sert fully charged battery. Be sure to repress fitting.
If LED’s continue to glow, contact Ridge Tool
Company, Technical Service Department at (800)
519-3456 for nearest Authorized Service outlet.
Push pressure release valve to remove jaws from fit-
ting. Inspect and repress fitting.
Install the correct jaw set.
Redo the joint with new fitting and new tube.
Make sure that the tool is square to the tube.
Redo the joint with new tube and new fitting.
Make sure the jaw contour is aligned with the
fitting contour.
Contact Ridge Tool Company, Technical Service
Department at (800) 519-3456 for nearest Author-
ized Service outlet.