Ridgid RP 330-C Owners Manual - Page 14

RP 330 Diagnostic Codes

Page 14 highlights

RP 330 Pressing Tool RP 330 Diagnostic Codes LED Green Status Glows Blinks Red Yellow Blinks Glows Blinks Glows Description Tool ON. Out of acceptable voltage range - Cordless Tools: Replace battery with a fully charged battery. - Corded Tools: Connect tool to a reliable voltage supply. If using extension cord, use 16 AWG for 50' or less, 14 AWG for 50' to 100'. Jaws mounting pin not fully engaged. Insert pin. Out of temperature range -10°C (15°F) to 50°C (122°F). Service indicator after 30,000 cycles. NOTE: Tool will lock after 32,000 cycles. Machine is locked - Service after 32,000 cycles or after a malfunction. 12 Ridge Tool Company

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43

Ridge Tool Company
12
RP 330 Pressing Tool
RP 330 Diagnostic Codes
LED
Status
Description
Green
Glows
Tool ON.
Blinks
Out of acceptable voltage range
— Cordless Tools: Replace battery with a fully charged battery.
— Corded Tools: Connect tool to a reliable voltage supply. If using extension cord,
use 16 AWG for 50' or less, 14 AWG for 50' to 100'.
Red
Blinks
Jaws mounting pin not fully engaged. Insert pin.
Glows
Out of temperature range -10°C (15°F) to 50°C (122°F).
Yellow
Blinks
Service indicator after 30,000 cycles. NOTE: Tool will lock after 32,000 cycles.
Glows
Machine is locked – Service after 32,000 cycles or after a malfunction.