Ryobi P4002 Operation Manual - Page 12

Maintenance, Operation - replacement cable

Page 12 highlights

OPERATION  Allow any liquids inside the drum to pour down a drain or into a container approved for liquid waste. To clean the cable:  Remove the battery pack or power cord from the tool.  Using a clean cloth and warm soapy water, pull the cable out from the tool, cleaning it as it advances. Continue until the cable has been fully advanced and completely cleaned.  Using a clean, dry cloth, pull the cable back into the tool, drying it as it retracts. Continue until the cable has been fully retracted.  To ensure that no water entered the tool, drain the drum as described earlier. NOTICE: Do not advance or retract the cable using the switch trigger unless the cable is in a drain pipe. MAINTENANCE WARNING: When servicing, use only identical replacement parts. Use of any other part could create a hazard or cause product damage. WARNING: To avoid serious personal injury, always remove the battery pack or power cord from the tool when cleaning, performing any maintenance, or when storing the tool. GENERAL MAINTENANCE Avoid using solvents when cleaning plastic parts. Most plastics are susceptible to damage from various types of commercial solvents and can be damaged by their use. Use clean cloths to remove dirt, dust, oil, grease, etc. WARNING: Do not at any time let brake fluids, gasoline, petroleumbased products, penetrating oils, etc., come in contact with plastic parts. Chemicals can damage, weaken or destroy plastic which could result in serious personal injury. REPLACING THE AUGER TIP After extended use, the auger tip may wear and need replacing. Refer to Removing/Installing Auger Tips earlier in this manual. REPLACING THE DRUM See Figures 11 - 12, page 14. If the cable becomes damaged or broken, replace the drum before attempting to operate the drain auger. To replace the drum:  Remove the battery pack or power cord from the tool.  Remove the auger tip as described earlier.  Pull the feed direction selector collar out and rotate it to the neutral (N) position.  Pull drum latch up to unlock the front portion of the tool. NOTE: When opening the latch, hold the drum securely to prevent the drum from falling out.  Move the front portion of the tool forward (away from the drum) and pivot it up.  Pull the cable through the feed direction selector collar and into the old drum.  Pull the old drum off the spindle and remove it from the tool.  Place the new drum onto the spindle.  Feed the cable for the new drum through the feed direction selector collar and toward the front of the tool.  Tilt the front portion of the tool down and slide it back into place (toward the drum).  Push the drum latch down to lock the front portion of the tool in place.  Ensure that the latch, drum, and front portion of the tool are secure before operating the tool. NOTE: ILLUSTRATIONS START ON PAGE 13 AFTER FRENCH AND SPANISH LANGUAGE SECTIONS. 12 - English

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

12 — English
NOTE: ILLUSTRATIONS START ON PAGE 13
AFTER FRENCH AND SPANISH LANGUAGE SECTIONS.
MAINTENANCE
REPLACING THE DRUM
See Figures 11 - 12, page 14.
If the cable becomes damaged or broken, replace the drum
before attempting to operate the drain auger.
To replace the drum:
Remove the battery pack or power cord from the tool.
Remove the auger tip as described earlier.
Pull the feed direction selector collar out and rotate it to
the neutral (
N
) position.
Pull drum latch up to unlock the front portion of the tool.
NOTE:
When opening the latch, hold the drum securely
to prevent the drum from falling out.
Move the front portion of the tool forward (away from the
drum) and pivot it up.
Pull the cable through the feed direction selector collar
and into the old drum.
Pull the old drum off the spindle and remove it from the
tool.
Place the new drum onto the spindle.
Feed the cable for the new drum through the feed
direction selector collar and toward the front of the tool.
Tilt the front portion of the tool down and slide it back
into place (toward the drum).
Push the drum latch down to lock the front portion of the
tool in place.
Ensure that the latch, drum, and front portion of the tool
are secure before operating the tool.
WARNING:
When servicing, use only identical replacement parts.
Use of any other part could create a hazard or cause
product damage.
WARNING:
To avoid serious personal injury, always remove the
battery pack or power cord from the tool when cleaning,
performing any maintenance, or when storing the tool.
GENERAL MAINTENANCE
Avoid using solvents when cleaning plastic parts. Most
plastics are susceptible to damage from various types of
commercial solvents and can be damaged by their use. Use
clean cloths to remove dirt, dust, oil, grease, etc.
WARNING:
Do not at any time let brake fluids, gasoline, petroleum-
based products, penetrating oils, etc., come in contact
with plastic parts. Chemicals can damage, weaken or
destroy plastic which could result in serious personal
injury.
REPLACING THE AUGER TIP
After extended use, the auger tip may wear and need
replacing. Refer to
Removing/Installing Auger Tips
earlier
in this manual.
OPERATION
Allow any liquids inside the drum to pour down a drain
or into a container approved for liquid waste.
To clean the cable:
Remove the battery pack or power cord from the tool.
Using a clean cloth and warm soapy water, pull the cable
out from the tool, cleaning it as it advances.
Continue
until the cable has been fully advanced and completely
cleaned.
Using a clean, dry cloth, pull the cable back into the tool,
drying it as it retracts. Continue until the cable has been
fully retracted.
To ensure that no water entered the tool, drain the drum
as described earlier.
NOTICE:
Do not advance or retract the cable using the switch
trigger unless the cable is in a drain pipe.