Adjusting the LCD Display Using MagicInfo To use MagicInfo with an TSn-3 model, install inside the product a network box specified by Samsung and connect the MagicInfo output on the network box to [HDMI IN 2 (MAGICINFO)] on the product. Multi Control Assigns an individual ID to the SET. • ID Setup Assigns distinctive IDs to the SET. • ID Input Use to select the transmitter functions of the individual SET. Only a SET where the ID corresponds to the transmitter setting becomes activated. • MDC Connection Selects a port to receive the MDC inputs from. • RS232C MDC - Communicates with the MDC via a RS232C MDC cable. • RJ45 MDC - Communicates with the MDC via an RJ45 MDC cable. • Network Setting • IP Setting : Manual, Auto • IP Address : Manually enter the IP Address if IP Setting is set to Manual. • Subnet Mask : Manually enter the Subnet Mask if IP Setting is set to Manual. • Gateway : Manually enter the Gateway if IP Setting is set to Manual. MagicInfo Available Modes • PC / DVI / DisplayPort • AV • Component • HDMI • MagicInfo