Sanyo PDG-DXL2000 RS232C Expand - Page 66

CR_TERMINAL Command, 11.15 CR_STANDBYMODE Command, 11.16 CR_P-MANE Command, 11.17 CR_P-

Page 66 highlights

PDG-DXL2000 Expand Serial Command Functional Specifications 9.11.14 CR_TERMINAL Command Command "CR_TERMINAL" [CR] Details Get setting status of Terminal Acceptable "000_%1"[CR] Response %1 "COMPUTER Computer Input mode "MONITOR Monitor Out mode Unacceptable "?"[CR] 9.11.15 CR_STANDBYMODE Command Command "CR_STANDBYMODE" [CR] Details Get Standby Mode setting status Acceptable "000_%a"[CR] Response %a "ECO Eco Mode "NORMAL" -------- Network Mode Unacceptable "Error code"[CR] 9.11.16CR_P-MANE Command Command "CR_P-MANE"[CR] Details Get Power management setting status Acceptable "000_%a"[CR] "OFF Power Management is OFF Response %a "READY Power Management is Ready "SHUTDOWN" ---- Power Management is set to Shut Down mode Unacceptable "Error code"[CR] 9.11.17 CR_P-MANETIME Command Command "CR_P-MANETIME"[CR] Details Get time to start Power Management Response Acceptable %a "000_%a"[CR] "001"~"030 1 minute to 30 minutes Unacceptable "Error code"[CR] 9.11.18 CR_ON-STA Command Command "CR_ON-STA"[CR] Details Get Direct on setting status Acceptable "000_%a"[CR] Response %a "ON Direct on is active "OFF Direct on is inactive Unacceptable "Error code"[CR] 65/72

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73

PDG-DXL2000
Expand Serial Command Functional Specifications
65/72
9.11.14 CR_TERMINAL Command
Command
“CR_TERMINAL” [CR]
Details
Get setting status of Terminal
Acceptable
“000_%1”[CR]
%1
“COMPUTER”-------------Computer Input mode
“MONITOR”----------------Monitor Out mode
Response
Unacceptable
“?”[CR]
9.11.15 CR_STANDBYMODE Command
Command
“CR_STANDBYMODE” [CR]
Details
Get Standby Mode setting status
Acceptable
“000_%a”[CR]
%a
“ECO” -------------- Eco Mode
“NORMAL” -------- Network Mode
Response
Unacceptable
“Error code”[CR]
9.11.16 CR_P-MANE Command
Command
“CR_P-MANE”[CR]
Details
Get Power management setting status
Acceptable
“000_%a”[CR]
%a
“OFF” -------------------------- Power Management is OFF
“READY” ---------------------- Power Management is Ready
“SHUTDOWN” ---- Power Management is set to Shut Down mode
Response
Unacceptable
“Error code”[CR]
9.11.17 CR_P-MANETIME Command
Command
“CR_P-MANETIME”[CR]
Details
Get time to start Power Management
Acceptable
“000_%a”[CR]
%a
“001”~”030” -----------------------1 minute to 30 minutes
Response
Unacceptable
“Error code”[CR]
9.11.18 CR_ON-STA Command
Command
“CR_ON-STA”[CR]
Details
Get Direct on setting status
Acceptable
“000_%a”[CR]
%a
“ON” ------------------------- Direct on is active
“OFF” ------------------------ Direct on is inactive
Response
Unacceptable
“Error code”[CR]