Sanyo PLC-HF15000L RS232 Basic - Page 18

[CR], 88 [CR], 2C [CR]

Page 18 highlights

PLC-HF15000L Basic Serial Command Functional Specifications "81" [CR] Status: Standby after Cooling Down due to lamp failure This value is returned when Cooling Down operation due to lamp failure has been completed and the status has been moved to Standby. The status is kept until the next operation starts. "88" [CR] Status: Standby after Cooling Down due to Abnormal Temperature This value is returned when Cooling Down operation due to Abnormal Temperature has been completed and the status has been moved to Standby. The status is kept until the next operation starts. "2C" [CR] Status: Cooling Down in process due to Shutter management function This indicates it has moved to Cooling down status according to the setting of Shutter Management function in setting menu. During this time, Functional Execution Commands are not accepted. "88" [CR] Status: Standby after Cooling Down due to Shutter management function This value is returned when Cooling Down operation due to Shutter management has been completed and the status has been moved to Standby. The status is kept until the next operation starts. When projector is turned on again, it cancels the last status and starts normal operation. 18/23

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23

PLC-HF15000L
Basic Serial Command Functional Specifications
18/23
“81” [CR]
Status: Standby after Cooling Down due to lamp failure
This value is returned when Cooling Down operation due to lamp failure has been
completed and the status has been moved to Standby. The status is kept until the next
operation starts.
“88” [CR]
Status: Standby after Cooling Down due to Abnormal Temperature
This value is returned when Cooling Down operation due to Abnormal Temperature has
been completed and the status has been moved to Standby. The status is kept until the
next operation starts.
“2C” [CR]
Status: Cooling Down in process due to Shutter management function
This indicates it has moved to Cooling down status according to the setting of Shutter
Management function in setting menu. During this time, Functional Execution Commands
are not accepted.
“88” [CR]
Status: Standby after Cooling Down due to Shutter management function
This value is returned when Cooling Down operation due to Shutter management has been
completed and the status has been moved to Standby. The status is kept until the next
operation starts. When projector is turned on again, it cancels the last status and starts
normal operation.