Sanyo PLC-XP100L Owners Manual - Page 80

Status Read Command, CR' [Command] 'CR

Page 80 highlights

Appendix Status Read Command Format The command is sent from PC to the projector with the format below; 'CR' [Command] 'CR' Command: one character (refer to the command table below. The projector decodes the command and returns the 'Charactor string' with the format below; Command CR0 CR6 Function Status Read Temperature Read Projector Return 00 80 40 20 10 28 24 04 21 81 88 S1 S2 S3 Projectro status Power On Stand-by mode Countdown Cooling down Power Malfunction Cooling down at the temperature anomaly Cooling down at Power Management mode Power Management mode after Cooling down Cooling down after the projector is turned off when the lamps are out. Stand-by mode after Cooling down when the lamps are out. Stand-by mode after Cooling down at the temperature anomaly. S1 = Temperature at Sensor 1 (˚C) S2 = Temperature at Sensor 2 (˚C) S3 = Temperature at Sensor 3 (˚C) (ex.) S1 = 12.3˚C, S2 = 23.4˚C, S3 = 34.5˚C --> The projector displays "12.3 23.4 34.5" (For each sensor, two digit and the tenth place numbers are displayed with a space between each temperature.) ? Communication failure The tables on page 79 and 80 show the typical command lists for controlling the projector. Please consult your local dealer for further information of other commands. 80

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81

80
Status Read Command
Appendix
The command is sent from PC to the projector with
the format below;
'CR' [Command] 'CR'
Command: one character (refer to the command
table below.
The projector decodes the command and returns the
'Charactor string' with the format below;
Format
Command
Function
Projector
Return
Projectro status
CR0
Status Read
00
Power On
80
Stand-by mode
40
Countdown
20
Cooling down
10
Power Malfunction
28
Cooling down at the temperature anomaly
24
Cooling down at Power Management mode
04
Power Management mode after Cooling down
21
Cooling down after the projector is turned off when the lamps
are out.
81
Stand-by mode after Cooling down when the lamps are out.
88
Stand-by mode after Cooling down at the temperature
anomaly.
CR6
Temperature Read
S1 S2 S3
S1 = Temperature at Sensor 1 (˚C)
S2 = Temperature at Sensor 2 (˚C)
S3 = Temperature at Sensor 3 (˚C)
(ex.) S1 = 12.3˚C,
S2 = 23.4˚C, S3 = 34.5˚C
--> The projector displays “12.3 23.4 34.5”
(For each sensor, two digit and the tenth place numbers are
displayed with a space between each temperature.)
?
Communication failure
The tables on page 79 and 80 show the typical command lists for controlling the projector.
Please consult your