Condition/Problem Console shuts off (enters sleep mode) while in use Fan will not turn on or will not turn off Fan will not turn on, but Console operates Things to Check Check electrical (wall) outlet Check connection at front of unit Check data cable integrity Check data cable connections/orientation Reset machine Check magnet position (requires shroud removal) Check Speed Sensor Check data cable integrity Check data cable connections/orientation Reset machine Check for blockage of fan Solution Make sure unit is plugged into a functioning wall outlet. Connection should be secure and undamaged. Replace adapter or connection at unit if either are damaged. All wires in the cable should be intact. If any are cut or crimped, replace cable. Be sure cable is connected securely and oriented properly. Small latch on connector should line up and snap into place. Unplug unit from electrical outlet for 3 minutes. Reconnect to outlet. Magnet should be in place on pulley. Contact Customer Care for further assistance. All wires in cable should be intact. If any are cut or crimped, replace cable. Be sure cable is connected securely and oriented properly. Small latch on connector should line up and snap into place. Unplug unit from electrical outlet for 3 minutes. Reconnect to outlet. Unplug unit from electrical outlet for 5 minutes. Remove material from fan. If necessary, detach the Console to help with removal. Replace the Console if unable to remove blockage. 48

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52

48
Condition/Problem
Things to Check
Solution
Console shuts off (enters
sleep mode) while in use
Check electrical (wall)
outlet
Make sure unit is plugged into a func-
tioning wall outlet.
Check connection at front
of unit
Connection should be secure and un-
damaged. Replace adapter or connec-
tion at unit if either are damaged.
Check data cable integrity
All wires in the cable should be intact. If
any are cut or crimped, replace cable.
Check data cable
connections/orientation
Be sure cable is connected securely
and oriented properly. Small latch on
connector should line up and snap into
place.
Reset machine
Unplug unit from electrical outlet for 3
minutes. Reconnect to outlet.
Check magnet position
(requires shroud removal)
Magnet should be in place on pulley.
Check Speed Sensor
Contact Customer Care for further
assistance.
Fan will not turn on or will
not turn off
Check data cable integrity
All wires in cable should be intact. If any
are cut or crimped, replace cable.
Check data cable
connections/orientation
Be sure cable is connected securely
and oriented properly. Small latch on
connector should line up and snap into
place.
Reset machine
Unplug unit from electrical outlet for 3
minutes. Reconnect to outlet.
Fan will not turn on, but
Console operates
Check for blockage of fan
Unplug unit from electrical outlet for 5
minutes. Remove material from fan. If
necessary, detach the Console to help
with removal. Replace the Console if