3.8 Start/stop times Time to ready Power-on to Ready (sec) Standby to Ready (sec) Typical 3.5 3.0 Max @ 25°C 4.0 3.0 3.9 Power specifications The drive receives DC power (+5V) through a native SATA power connector. 3.9.1 Power consumption Power requirements for the drives are listed in the table on page 8. Typical power measurements are based on an average of drives tested, under nominal conditions, at 25°C ambient temperature. These power measurements are done with Interface Power Management modes like HIPM and DIPM enabled. • Spinup power Spinup power is measured from the time of power-on to the time that the drive spindle reaches operating speed. • Seek mode During seek mode, the read/write actuator arm moves toward a specific position on the disk surface and does not execute a read or write operation. Servo electronics are active. Seek mode power is measured based on three random seek operations every 100ms. This mode is not typical. • Read/write power and current Read/write power is measured with the heads on track, based on three 63 sector read or write operations every 100ms. • Idle mode power Idle mode power is measured with the drive up to speed, with servo electronics active and with the heads in a random track location. • Standby mode During Standby mode, the drive accepts commands, but the drive is not spinning, and the servo and read/ write electronics are in power-down model Table 3: DC power Power dissipation Spinup (max) Seek Read Write Idle, performance* Idle, active* Idle, low power mode* Standby** Sleep +5V input average (25° C) 1.00A 1.6W 1.6W 1.9W 1.3W 0.90W 0.66W 0.15W 0.15W *During periods of drive idle, some offline activity may occur according to the S.M.A.R.T. specification, which may increase acoustic and 8 Momentus Thin Product Manual, Gen-2 Rev. D

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46

8
Momentus Thin Product Manual, Gen-2 Rev. D
3.8
Start/stop times
Time to ready
Typical
Max @ 25
°
C
Power-on to Ready (sec)
3.5
4.0
Standby to Ready (sec)
3.0
3.0
3.9
Power specifications
The drive receives DC power (+5V) through a native SATA power connector.
3.9.1
Power consumption
Power requirements for the drives are listed in the table on page 8. Typical power measurements are based on
an average of drives tested, under nominal conditions, at 25°C ambient temperature. These power measure-
ments are done with Interface Power Management modes like HIPM and DIPM enabled.
Spinup power
Spinup power is measured from the time of power-on to the time that the drive spindle reaches operating speed.
Seek mode
During seek mode, the read/write actuator arm moves toward a specific position on the disk surface and does
not execute a read or write operation. Servo electronics are active. Seek mode power is measured based on
three random seek operations every 100ms. This mode is not typical.
Read/write power and current
Read/write power is measured with the heads on track, based on three 63 sector read or write operations
every 100ms.
Idle mode power
Idle mode power is measured with the drive up to speed, with servo electronics active and with the heads in
a random track location.
Standby mode
During Standby mode, the drive accepts commands, but the drive is not spinning, and the servo and read/
write electronics are in power-down model
Table 3:
DC power
Power dissipation
+5V input average (25° C)
Spinup (max)
1.00A
Seek
1.6W
Read
1.6W
Write
1.9W
Idle, performance*
1.3W
Idle, active*
0.90W
Idle, low power mode*
0.66W
Standby**
0.15W
Sleep
0.15W
*During periods of drive idle, some offline activity may occur according to the S.M.A.R.T. specification, which may increase acoustic and