Seagate ST160LT007 Momentus Thin (.2-4K) SATA Product Manual - Page 32

Supported ATA commands

Page 32 highlights

6.3 Supported ATA commands The following table lists Serial ATA standard commands that the drive supports. For a detailed description of the ATA commands, refer to the Serial ATA: High Speed Serialized AT Attachment specification. See "S.M.A.R.T. commands" on page 33.for details and subcommands used in the S.M.A.R.T. implementation. Command name Command code (in hex) ATA-standard commands Device Configuration Restore B1h/C0h Device Configuration Freeze Lock B1h/C1h Device Configuration Identify B1h/C2h Device Configuration Set B1h/C3h Download Microcode 92h Execute Device Diagnostics 90h Flush Cache E7h Flush Cache Extended EAh Identify Device ECh Initialize Device Parameters 91h Read Buffer E4h Read DMA C8h Read DMA Extended 25h Read DMA without Retries C9h Read Long with Retries 22h Read Long without Retries 23h Read Multiple C4h Read Multiple Extended 29h Read Native Max Address F8h Read Native Max Address Extended 27h Read Sectors 20h Read Sectors Extended 24h Read Sectors without Retries 21h Read Verify Sectors 40h Read Verify Sectors Extended 42h Read Verify Sectors without Retries 41h Seek 70h Set Features EFh Set Max Address F9h Note: Individual Set Max commands are identi- Address: 00H fied by the value placed in the Set Max Fea- Password: 01H tures register as defined to the right. Lock: 02H Unlock: 03H Freeze Lock: 04H Set Multiple Mode C6h S.M.A.R.T. Disable Operations B0h/D9h S.M.A.R.T. Enable/Disable Autosave B0h/D2h 26 Momentus Thin Product Manual, Gen-2 Rev. D

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46

26
Momentus Thin Product Manual, Gen-2 Rev. D
6.3
Supported ATA commands
The following table lists Serial ATA standard commands that the drive supports. For a detailed description of
the ATA commands, refer to the Serial ATA: High Speed Serialized AT Attachment specification
.
See
“S.M.A.R.T. commands” on page 33.for details and subcommands used in the S.M.A.R.T. implementation.
Command name
Command code (in hex)
ATA-standard commands
Device Configuration Restore
B1h/C0h
Device Configuration Freeze Lock
B1h/C1h
Device Configuration Identify
B1h/C2h
Device Configuration Set
B1h/C3h
Download Microcode
92h
Execute Device Diagnostics
90h
Flush Cache
E7h
Flush Cache Extended
EAh
Identify Device
ECh
Initialize Device Parameters
91h
Read Buffer
E4h
Read DMA
C8h
Read DMA Extended
25h
Read DMA without Retries
C9h
Read Long with Retries
22h
Read Long without Retries
23h
Read Multiple
C4h
Read Multiple Extended
29h
Read Native Max Address
F8h
Read Native Max Address Extended
27h
Read Sectors
20h
Read Sectors Extended
24h
Read Sectors without Retries
21h
Read Verify Sectors
40h
Read Verify Sectors Extended
42h
Read Verify Sectors without Retries
41h
Seek
70h
Set Features
EFh
Set Max Address
F9h
Note: Individual Set Max commands are identi-
fied by the value placed in the Set Max Fea-
tures register as defined to the right.
Address:
Password:
Lock:
Unlock:
Freeze Lock:
00
H
01
H
02
H
03
H
04
H
Set Multiple Mode
C6h
S.M.A.R.T. Disable Operations
B0h/D9h
S.M.A.R.T. Enable/Disable Autosave
B0h/D2h