Sharp UP-820N UP-820N Operation Manual - Page 139
Combo meal table continued, Scale table
View all Sharp UP-820N manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 139 highlights
Combo meal table (continued) • COMBO PLU#1-9 (Use the numeric entry method) Select associated PLUs (max. 9 PLUs) from the list. • PRICE1 (Use the numeric entry method) Unit price of each associated PLU (max. 6 digits). • PRICE2 (Use the numeric entry method) 2nd unit price (for Upsize function) of each associated PLU (max. 6 digits). NOTE • The PRICE1 is selected by the combo meal entry. When the UPSIZE key is pressed after the combo meal entry, the entry of PRICE1 is voided and a new entry of PRICE2 is registered. • PLU codes should be defined before programming a combo meal table. • If the (DEL) key is pressed on the table number selection menu, the programmed data in the cursor position will be deleted. Scale table The POS terminal can be programmed with up to nine tare tables and allows different tares to be assigned to scalable items (for auto scale entries). Procedure Program each item as follows: • SCALE TABLE (Use the numeric entry method) Tare table number (1 thru 9) • WEIGHT (Use the numeric entry method) Enter a tare weight for the scale table number (max. 4 digits: 1 to 99.99 lbs.). Selected tare table (ENTER) number NOTE Your POS terminal may also be set to accommodate 1-integer + 3decimal weights. For more details, please consult your authorized SHARP dealer. - 137 -